Comparison of ion coupling strategies for a microengineered quadrupole mass filter.

Steven Wright1, Richard R A Syms, Shane O'Prey, Guodong Hong, Andrew S Holmes.   

Abstract

The limitations of conventional machining and assembly techniques require that designs for quadrupole mass analyzers with rod diameters less than a millimeter are not merely scale versions of larger instruments. We show how silicon planar processing techniques and microelectromechanical systems (MEMS) design concepts can be used to incorporate complex features into the construction of a miniature quadrupole mass filter chip that could not easily be achieved using other microengineering approaches. Three designs for the entrance and exit to the filter consistent with the chosen materials and techniques have been evaluated. The differences between these seemingly similar structures have a significant effect on the performance. Although one of the designs results in severe attenuation of transmission with increasing mass, the other two can be scanned to m/z = 400 without any corruption of the mass spectrum. At m/z = 219, the variation in the transmission of the three designs was found to be approximately four orders of magnitude. A maximum resolution of M/DeltaM = 87 at 10% peak height has been achieved at m/z = 219 with a filter operated at 6 MHz and constructed using rods measuring (508 +/- 5) microm in diameter.

Year:  2008        PMID: 18838276     DOI: 10.1016/j.jasms.2008.08.019

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  8 in total

1.  Rapid Commun. Mass Spectrom. 13, 740 ?lpar;1999?rpar; by J. W. Hager, ?ldquo;Performance Optimization and Fringing Field Modifications of a 24?hyphen;mm Long RF?hyphen;only Quadrupole Mass Spectrometer?rdquo;

Authors: 
Journal:  Rapid Commun Mass Spectrom       Date:  1999-06       Impact factor: 2.419

2.  Miniature mass analyzers

Authors: 
Journal:  J Mass Spectrom       Date:  2000-06       Impact factor: 1.982

3.  Trade-offs in miniature quadrupole designs.

Authors:  S Boumsellek; R J Ferran
Journal:  J Am Soc Mass Spectrom       Date:  2001-06       Impact factor: 3.109

4.  Axial ion focusing in a miniature linear ion trap.

Authors:  Gareth S Dobson; Christie G Enke
Journal:  Anal Chem       Date:  2007-04-13       Impact factor: 6.986

5.  Planar ion microtraps.

Authors: 
Journal:  Phys Rev A       Date:  1992-12-01       Impact factor: 3.140

6.  A quadrupole ion trap with cylindrical geometry operated in the mass-selective instability mode.

Authors:  J M Wells; E R Badman; R G Cooks
Journal:  Anal Chem       Date:  1998-02-01       Impact factor: 6.986

7.  A miniature cylindrical quadrupole ion trap:  simulation and experiment.

Authors:  E R Badman; R C Johnson; W R Plass; R G Cooks
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

8.  Microfabricated quadrupole ion trap for mass spectrometer applications.

Authors:  S Pau; C S Pai; Y L Low; J Moxom; P T A Reilly; W B Whitten; J M Ramsey
Journal:  Phys Rev Lett       Date:  2006-03-31       Impact factor: 9.161

  8 in total