Literature DB >> 18836374

Unexpected 99mTc-tetrofosmin findings during myocardial perfusion scintigraphy: intraindividual comparison with PET/computed tomography.

Stefan Gratz1, Bendix Kempke, Wolf Kaiser, Thomas M Behr, Andreas Pfestroff, Helmut Höffken.   

Abstract

OBJECTIVE: 99mTc-tetrofosmin single photon emission computed tomography (SPECT) is routinely used in the evaluation of coronary artery disease. A variety of different tumors, however, also demonstrate 99mTc-tetrofosmin uptake. We report six patients found with unexpected mediastinal and thoracic tumor uptake during Tc-tetrofosmin myocardial perfusion scintigraphy (MPS).
MATERIALS AND METHODS: We investigated 2,155 patients with Tc-tetrofosmin MPS during 2006-2007. One thousand four hundred and eighty-six of these patients had no coronary history and were sent to our department due to newly developed thoracic complaint such as chest pain, dyspnea and others. Six hundred and sixty-nine patients had coronary history. All patients underwent 99mTc-tetrofosmin exercise study. Patients with unexpected extracardiac Tc-tetrofosmin findings during MPS were referred to PET/CT for further diagnostic investigation. Region of interest (ROI; 99mTc-tetrofosmin) and SUVmax (2-[F]fluoro-2-deoxy-D-glucose, F-FDG) were estimated and the results were compared with histological findings.
RESULTS: Abnormal mediastinal and/or thoracic activities were visualized in six of the 2,155 patients with 99mTc-tetrofosmin images. Subsequently, the patients underwent resection of a thymoma (n=2), nonsmall cell lung cancer (n=1) and breast cancer (n=3). In the patients with breast cancer one was a male patient with ductal, invasive breast cancer. Benign thymomas showed high 99mTc-tetrofosmin ROI >4.0 and low F-FDG SUVmax <2.0, whereas low 99mTc-tetrofosmin ROI <2.0 were found in nonsmall cell lung cancer and breast cancer and high F-FDG SUVmax >2.5 in these malignant tumors.
CONCLUSION: During Tc-tetrofosmin SPECT exercise stress tests performed in patients with suspected coronary artery disease, much more attention must be given to unexpected extracardiac uptakes. With 99mTc-tetrofosmin a large variety of different unknown tumors can be detected during MPS.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18836374     DOI: 10.1097/MNM.0b013e32830b0c45

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

1.  Early cardiac metastasis from squamous cell carcinoma of the tongue in 2 patients.

Authors:  Jean Onwuchekwa; Jose Banchs
Journal:  Tex Heart Inst J       Date:  2012

2.  Mediastinal thymoma diagnosed with Tc-99m tetrofosmin SPECT myocardial perfusion imaging.

Authors:  Elsayed Abo-Salem; Myron Gerson
Journal:  J Nucl Cardiol       Date:  2014-07-31       Impact factor: 5.952

3.  Incidental detection of bronchial carcinoid on Tc-99m sestamibi SPECT/CT myocardial perfusion scintigraphy.

Authors:  Dharmender Malik; Apurva Sood; Madan Parmar; Ashwani Sood; Bishan Radotra; Bhagwant Mittal
Journal:  J Nucl Cardiol       Date:  2016-02-17       Impact factor: 5.952

4.  Decreased myocardial perfusion SPECT lung-to-heart ratio: Lucent lungs.

Authors:  Brian Wosnitzer; Gordon DePuey
Journal:  Radiol Case Rep       Date:  2015-12-07
  4 in total