Comparison of pinhole and SPECT 99mTc-MIBI imaging in primary hyperparathyroidism.

Ivan A Ho Shon1, Warren Yan, Paul J Roach, Elizabeth J Bernard, Melissa Shields, Mark Sywak, Stanley Sidhu, Leigh W Delbridge.   

Abstract

OBJECTIVE: This study aims to compare dual tracer, dual phase pinhole technetium-99m labelled 2-methoxyisobutylisonitrile (Tc-MIBI) imaging (including oblique imaging), with single photon emission computed tomography (SPECT) and dual phase planar Tc-MIBI images, and combined SPECT, dual phase planar Tc-MIBI images and anterior pinhole thyroid images for the localization of parathyroid adenomas in the neck in primary hyperparathyroidism.
METHODS: Sixty-two patients underwent Tc-MIBI dual phase, anterior and anterior oblique pinhole images of the neck, anterior planar images of the neck and chest and early phase neck/chest SPECT followed by [Tc] pertechnetate anterior and anterior oblique pinhole thyroid images. Images were reviewed by consensus in three combinations - dual phase anterior and anterior oblique pinhole Tc-MIBI images and pinhole thyroid images; SPECT and dual phase planar Tc-MIBI images and combined SPECT, dual phase planar Tc-MIBI images and anterior pinhole thyroid images.
RESULTS: For 52 parathyroid adenomas in 50 patients, the sensitivity of dual phase anterior and anterior oblique pinhole Tc-images and pinhole thyroid images was 81%. Significantly lower sensitivities were observed with SPECT and dual phase planar Tc-MIBI images (54%, P=0.0005) and combined SPECT, dual phase planar Tc-MIBI images and anterior pinhole thyroid images (65%, P=0.0209). The positive predictive value for all imaging combinations was 88-92%.
CONCLUSION: Dual phase anterior and anterior oblique pinhole Tc-MIBI images and pinhole thyroid images are significantly more sensitive than imaging combinations that included SPECT and remains the optimal imaging protocol for the localization of parathyroid adenomas in the neck in primary hyperparathyroidism.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18836372     DOI: 10.1097/MNM.0b013e328309789e

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  4 in total

Review 1.  Imaging for primary hyperparathyroidism--an evidence-based analysis.

Authors:  Radu Mihai; Dietmar Simon; Per Hellman
Journal:  Langenbecks Arch Surg       Date:  2009-07-10       Impact factor: 3.445

2.  Comparison of five parathyroid scintigraphic protocols.

Authors:  Virpi Tunninen; Pekka Varjo; Jukka Schildt; Aapo Ahonen; Tomi Kauppinen; Irina Lisinen; Anu Holm; Hannu Eskola; Marko Seppänen
Journal:  Int J Mol Imaging       Date:  2013-01-21

3.  Comparison of Tc-99m pertechnetate images with dual-phase Tc 99m MIBI and SPECT images in primary hyperparathyroidism.

Authors:  Sait Sager; Hojjat Shafipour; Sertac Asa; Sabire Yılmaz; Serkan Teksöz; Cetin Onsel
Journal:  Indian J Endocrinol Metab       Date:  2014-07

4.  Number of Foci of Functioning Thyroid Tissue Remaining after Thyroidectomy for Differentiated Thyroid Cancer: Institutional Experience.

Authors:  Kanchan Kulkarni; Gauri Khorjekar; Mihriye Mete; Douglas Van Nostrand
Journal:  World J Nucl Med       Date:  2017 Apr-Jun
  4 in total