Literature DB >> 18834870

Diagnostic accuracy of the urinary albumin: creatinine ratio determined by the CLINITEK Microalbumin and DCA 2000+ for the rule-out of albuminuria in chronic kidney disease.

Mark Guy1, Ronald Newall, Joanna Borzomato, Philip A Kalra, Christopher Price.   

Abstract

An increased urinary albumin excretion (albuminuria) is an established test for the early detection of renal disease and is also recognized as a risk factor for cardiovascular disease and mortality in a number of clinical settings. There is an established body of data which shows that a random urinary albumin:creatinine ratio (ACR) based on a random urine sample correlates well with 24-hour urinary albumin excretion measurement. However, there is little data to show whether specific point-of-care testing devices can be used to rule-in or rule-out increased urinary albumin excretion in comparison to a 24-hour urinary albumin excretion measurement. This study evaluated the ability to rule-in or rule-out albuminuria in a cohort of patients attending a renal outpatient clinic, using the urinary ACR determined by the CLINITEK Microalbumin (Siemens Healthcare Diagnostics Inc., Deerfield, US) a semi-quantitative strip test, and by the DCA 2000+ (Siemens Healthcare Diagnostics Inc.) a quantitative cassette based test using 3 random urine samples collected within a 24-hour period compared to 24-hour urinary albumin measurement. The CLINITEK system was shown to be a reliable test for ruling out increased urinary albumin excretion with negative likelihood ratios less than 0.05 above the 24-hour urinary albumin excretion rate of 30 mg/24 h (threshold for microalbuminuria), and less than 0.01 above the albumin excretion rate of 100 mg/24 h. The DCA 2000+ system demonstrated similar performance as a rule-out test, with likelihood ratios of less than 0.02 at 24-hour albumin excretion rates above 30 mg/24 h. Both the CLINITEK and DCA 2000+ systems could be used to rule-out increased urinary albumin excretion at the albumin excretion cut-off rate of 30 mg/24 h in this cohort of patients.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18834870     DOI: 10.1016/j.cca.2008.09.006

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  11 in total

1.  Chapter 1: Definition and classification of CKD.

Authors: 
Journal:  Kidney Int Suppl (2011)       Date:  2013-01

2.  Second Morning ACR Could Be the Alternative to First Morning ACR to Assess Albuminuria in Elderly Population.

Authors:  Hua-Bin Wang; Rong Li; Rui Liu; Xiao-Fan Cui; Wen-Jie Pan; Ao Sun
Journal:  J Clin Lab Anal       Date:  2015-01-14       Impact factor: 2.352

Review 3.  Urinary strips for protein assays: easy to do but difficult to interpret!

Authors:  Guillaume Résimont; Laurence Piéroni; Edith Bigot-Corbel; Etienne Cavalier; Pierre Delanaye
Journal:  J Nephrol       Date:  2020-04-23       Impact factor: 3.902

4.  An improved microalbumin method (microALB_2) with extended analytical measurement range evaluated on the ADVIA chemistry systems.

Authors:  Pradip Datta; Amitava Dasgupta
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

5.  Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa.

Authors:  June Fabian; Jaya A George; Sean D Currin; Mwawi S Gondwe; Nokthula B Mayindi; Shingirai Chipungu; Bongekile L Khoza; Stephen Tollman
Journal:  BMC Nephrol       Date:  2021-03-20       Impact factor: 2.388

6.  Hypertensive nephropathy treatment by heart-protecting musk pill: a study of anti-inflammatory therapy for target organ damage of hypertension.

Authors:  Dengke Tian; Shuang Ling; Gangling Chen; Yajuan Li; Jun Liu; Murad Ferid; Ka Bian
Journal:  Int J Gen Med       Date:  2011-02-15

7.  Chapter 3: Management of progression and complications of CKD.

Authors: 
Journal:  Kidney Int Suppl (2011)       Date:  2013-01

8.  Comparison of Urine Albumin-to-Creatinine Ratio (ACR) Between ACR Strip Test and Quantitative Test in Prediabetes and Diabetes.

Authors:  Eun Hee Nah; Seon Cho; Suyoung Kim; Han Ik Cho
Journal:  Ann Lab Med       Date:  2017-01       Impact factor: 3.464

Review 9.  Progress in Automated Urinalysis.

Authors:  Matthijs Oyaert; Joris Delanghe
Journal:  Ann Lab Med       Date:  2019-01       Impact factor: 3.464

10.  Cost effectiveness of medical devices to diagnose pre-eclampsia in low-resource settings.

Authors:  Zoë M McLaren; Alana Sharp; John P Hessburg; Amir Sabet Sarvestani; Ethan Parker; James Akazili; Timothy R B Johnson; Kathleen H Sienko
Journal:  Dev Eng       Date:  2017-07-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.