Literature DB >> 18833761

Non-linear viscoelastic finite element analysis of the effect of the length of glass fiber posts on the biomechanical behaviour of directly restored incisors and surrounding alveolar bone.

Marco Ferrari1, Roberto Sorrentino, Fernando Zarone, Davide Apicella, Raffaella Aversa, Antonio Apicella.   

Abstract

The study aimed at estimating the effect of insertion length of posts with composite restorations on stress and strain distributions in central incisors and surrounding bone. The typical, average geometries were generated in a FEA environment. Dentin was considered as an elastic orthotropic material, and periodontal ligament was coupled with nonlinear viscoelastic mechanical properties. The model was then validated with experimental data on displacement of incisors from published literature. Three post lengths were investigated in this study: root insertion of 5, 7, and 9 mm. For control, a sound incisor model was generated. Then, a tearing load of 50 N was applied to both sound tooth and simulation models. Post restorations did not seem to affect the strain distribution in bone when compared to the control. All simulated post restorations affected incisor biomechanics and reduced the root's deforming capability, while the composite crowns underwent a higher degree of deformation than the sound crown. No differences could be noticed in incisor stress and strain. As for the influence of post length, it was not shown to affect the biomechanics of restored teeth.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18833761     DOI: 10.4012/dmj.27.485

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  7 in total

1.  Interpreting finite element results for brittle materials in endodontic restorations.

Authors:  Antonio Pérez-González; José L Iserte-Vilar; Carmen González-Lluch
Journal:  Biomed Eng Online       Date:  2011-06-02       Impact factor: 2.819

Review 2.  Post and core build-ups in crown and bridge abutments: Bio-mechanical advantages and disadvantages.

Authors:  John Mamoun
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

3.  Evaluation of Different Restoration Combinations Used in the Reattachment of Fractured Teeth: A Finite Element Analysis.

Authors:  Nagihan Guven; Ozgur Topuz; İhsan Yikilgan
Journal:  Appl Bionics Biomech       Date:  2018-03-15       Impact factor: 1.781

4.  In vitro evaluation of ferrule effect and depth of post insertion on fracture resistance of fiber posts.

Authors:  R Schiavetti; G Sannino
Journal:  Comput Math Methods Med       Date:  2012-12-02       Impact factor: 2.238

5.  Analysis of bond strength by pull out test on fiber glass posts cemented in different lengths.

Authors:  Mariana Benedetti Ferreira Webber; Silvia Masae de Araújo Michida; Fabiano Carlos Marson; Giovani Corrêa de Oliveira; Cleverson de Oliveira E Silva
Journal:  J Int Oral Health       Date:  2015-04

6.  Viscoelasticity of periodontal ligament: an analytical model.

Authors:  Sergei M Bosiakov; Anna A Koroleva; Sergei V Rogosin; Vadim V Silberschmidt
Journal:  Mech Adv Mater Mod Process       Date:  2015-11-16

7.  In vitro fracture resistance of zirconia, glass-fiber, and cast metal posts with different lengths.

Authors:  Ashutosh B Palepwad; Rahul Shyamrao Kulkarni
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.