Literature DB >> 18832969

Fluorescein pattern interpretation in keratoconus.

Barbara Fink1, Cynthia Heard, Jeff Schafer, Ame Richardson Cline, Lynn Mitchell, Joseph T Barr.   

Abstract

PURPOSE: The purpose of this study is to assess the effect of disease severity on how accurately contact lens fluorescein patterns can be interpreted in keratoconus by clinician assessment.
METHODS: Two clinicians evaluated fluorescein patterns on 111 eyes of 60 patients with mild (<45 D, 14 eyes), moderate (45 D to 52 D, 61 eyes,) and severe (>52 D, 36 eyes) keratoconus. The masked clinicians were given six contact lenses in random order, the lens that just cleared the corneal apex (the first definite apical clearance lens), three lenses flatter (in 0.1 mm increments), and two lenses steeper (in 0.1 mm increments) than the first definite apical clearance lens. They ranked the lenses from flattest to steepest, based on the fluorescein patterns. The percentage of lenses correctly ranked was determined using (1) exact match with actual; (2) within 0.1 mm of actual; and (3) within 0.2 mm of actual. Accuracy was assessed as the sum of the squared differences between the actual base curve value and each clinician's ranking. Comparison of the mean percentage correctly ranked and accuracy for each keratoconus severity groups was performed using a mixed linear model.
RESULTS: Neither percentage correctly ranked (using any of the three protocols) nor accuracy was found to be related to severity of keratoconus (p > 0.15 for all comparisons).
CONCLUSIONS: Accuracy of ranking contact lenses in order of base curve radius based on fluorescein pattern assessment by clinicians does not seem to be related to severity of keratoconus. Many factors influence interpretation of fluorescein patterns including all components of the system, fluorescein, tears, cornea, contact lens, external forces, and technique.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18832969     DOI: 10.1097/OPX.0b013e3181886fb6

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  1 in total

1.  Effects of fluorescein staining on laser in vivo confocal microscopy images of the cornea.

Authors:  Christine W Sindt; D Brice Critser; Trudy K Grout; Jami R Kern
Journal:  J Ophthalmol       Date:  2012-01-26       Impact factor: 1.909

  1 in total