Literature DB >> 18829300

Direct electrochemistry of myoglobin based on ionic liquid-clay composite films.

Zong Dai1, Yun Xiao, Xiaozhi Yu, Zhibin Mai, Xiaojuan Zhao, Xiaoyong Zou.   

Abstract

The direct electron transfer of myoglobin (Mb) was realized by immobilizing Mb onto ionic liquid (1-butyl-3-methyl imidazolium tetrafluoraborate, [bmim][BF(4)])-clay composite film modified glassy carbon electrode. A pair of well-defined redox peaks of Mb with a formal potential (E(o)') of -0.297 V (vs. Ag/AgCl) was observed in 0.1M phosphate buffer solution (pH 6.0). The ionic liquid-clay composite film showed good biocompatibility and an obvious promotion capability for the direct electron transfer between Mb and electrode. The electron transfer rate constant (k(s)) of Mb was calculated to be (3.58+/-0.12)s(-1). UV-vis spectrum suggested that Mb retained its native conformation in the ionic liquid-clay system. Basal plane spacing of clay obtained by X-ray diffraction (XRD) indicated that there was an intercalation-exfoliation-restacking process, in ionic liquid and clay during the drying process of the modification, and the ionic liquid played the key role for promotion of the direct electron transfer between Mb and the ionic liquid-clay composite film modified electrode. The biocatalytic activity of Mb in the composite film was exemplified by the reduction of hydrogen peroxide. Under the optimal conditions, the reduction peak currents of Mb increased linearly with the concentration of H(2)O(2) in the range of 3.90 x 10(-6) to 2.59 x 10(-4)M, with a detection limit of 7.33 x 10(-7)M. The kinetic parameter I(max) and the apparent Michaelis constant (K(m)) for the electrocatalytic reactions were 3.87 x 10(-8)A and 17.6 microM, respectively. The proposed method would be valuable for the construction of a new third-generation H(2)O(2) sensor.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18829300     DOI: 10.1016/j.bios.2008.08.032

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Fabrication of Electrochemical-Based Bioelectronic Device and Biosensor Composed of Biomaterial-Nanomaterial Hybrid.

Authors:  Mohsen Mohammadniaei; Chulhwan Park; Junhong Min; Hiesang Sohn; Taek Lee
Journal:  Adv Exp Med Biol       Date:  2018       Impact factor: 2.622

2.  Immobilization of myoglobin on Au nanoparticle-decorated carbon nanotube/polytyramine composite as a mediator-free H2O2 and nitrite biosensor.

Authors:  A T Ezhil Vilian; Vediyappan Veeramani; Shen-Ming Chen; Rajesh Madhu; Cheol Hwan Kwak; Yun Suk Huh; Young-Kyu Han
Journal:  Sci Rep       Date:  2015-12-17       Impact factor: 4.379

3.  Label-Free, Highly Sensitive Electrochemical Aptasensors Using Polymer-Modified Reduced Graphene Oxide for Cardiac Biomarker Detection.

Authors:  Abhinav Sharma; Jyoti Bhardwaj; Jaesung Jang
Journal:  ACS Omega       Date:  2020-02-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.