Literature DB >> 18828957

Frequency of self-monitoring of blood glucose in patients with type 2 diabetes: association with hypoglycaemic events.

Andrew Farmer1, Elizabeth Balman, Roger Gadsby, Jane Moffatt, Sue Cradock, Lisa McEwen, Kevin Jameson.   

Abstract

OBJECTIVE: The objective of this study is to describe current self-monitoring of blood glucose (SMBG) practice for patients with type 2 diabetes by treatment type and adherence with healthcare professional advice concerning SMBG. In addition, the study aims to investigate the association of SMBG and self-reported episodes of low blood glucose. DESIGN AND
SETTING: This cross-sectional survey design study was carried out on patients with type 2 diabetes aged 18 years or over, attending community pharmacies in 97 sites across the United Kingdom.
METHODS: Patients picking up a prescription for blood glucose test strips or diabetes medicine from a community pharmacist were asked to complete a questionnaire. The pharmacist was available to assist if requested. Questions included: self-reports of frequency of blood glucose testing; type of diabetes treatment; advice given by healthcare professionals about frequency of blood glucose testing; frequency of episodes of low blood glucose; and last known HbA(1c) level. The final sample size was 554 respondents, who were grouped for analysis as follows: those being treated with insulin, either alone or with any oral medication (n = 167); those being treated with sulfonylureas, either alone or with any oral medication (n = 187); and those being treated with any other medication, or controlled by diet and exercise alone (n = 202).
RESULTS: Frequency of SMBG was higher in patients using insulin (median 10 times per week, Q (1), Q (3) = 4.5, 14) than in patients on treatments other than insulin (four times per week, Q (1), Q (3) = 2, 7, p < 0.001). SMBG was carried out at the same frequency in patients not treated with insulin regardless of whether they were prescribed sulfonylureas. Greater frequency of SMBG was associated with self-reports of one or more episodes of low blood glucose in the previous six months.
CONCLUSIONS: Among patients with type 2 diabetes, those treated with insulin used SMBG at a greater frequency than those not treated with insulin. Increased frequency of testing was associated with increased frequency of self-reported episodes of low blood glucose, even among patients not taking insulin or sulfonylureas. This raises the possibility that episodes of hypoglycaemia may not be accurately identified, leading to unnecessary fear, or conversely that treatment is not being adjusted to avoid such morbidity. Although further work is needed to explore this association in a representative, prospective cohort of patients, possible explanations for reports of low-blood glucose should be discussed with patients using SMBG more frequently to ensure they are able to accurately identify episodes of hypoglycaemia.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18828957     DOI: 10.1185/03007990802473062

Source DB:  PubMed          Journal:  Curr Med Res Opin        ISSN: 0300-7995            Impact factor:   2.580


  8 in total

1.  Pan-European Economic Analysis to Identify Cost Savings for the Health Care Systems as a Result of Integrating Glucose Monitoring Based Telemedical Approaches Into Diabetes Management.

Authors:  Katharina Fritzen; Kornelia Basinska; Matilde Rubio-Almanza; Antonio Nicolucci; Brian Kennon; Bruno Vergès; Katerina Zakrzewska; Oliver Schnell
Journal:  J Diabetes Sci Technol       Date:  2019-03-27

2.  Patient Perspectives on Self-Monitoring of Blood Glucose When not Using Insulin: a Cross-sectional Survey.

Authors:  Elizabeth R Pfoh; Debra Linfield; Sidra L Speaker; Joud S Roufael; Chen Yan; Anita D Misra-Hebert; Michael B Rothberg
Journal:  J Gen Intern Med       Date:  2021-08-13       Impact factor: 6.473

3.  Adherence to self-monitoring of blood glucose in Chinese patients with type 2 diabetes: current status and influential factors based on electronic questionnaires.

Authors:  Xin Wang; Jun-Fei Luo; Lin Qi; Qing Long; Jia Guo; Hong-Hong Wang
Journal:  Patient Prefer Adherence       Date:  2019-07-25       Impact factor: 2.711

4.  The Effect of a Cellular-Enabled Glucose Meter on Glucose Control for Patients With Diabetes: Prospective Pre-Post Study.

Authors:  Jennifer B Bollyky; Stephanie T Melton; Tong Xu; Stefanie L Painter; Brian Knox
Journal:  JMIR Diabetes       Date:  2019-10-07

5.  Risk of any hypoglycaemia with newer antihyperglycaemic agents in patients with type 2 diabetes: A systematic review and meta-analysis.

Authors:  Sanaz Kamalinia; Robert G Josse; Patrick J Donio; Lindsay Leduc; Baiju R Shah; Sheldon W Tobe
Journal:  Endocrinol Diabetes Metab       Date:  2019-11-13

6.  One Hundred Years of Insulin: Value Beyond Price in Type 2 Diabetes Mellitus.

Authors:  Marc Evans; Angharad R Morgan; Stephen C Bain
Journal:  Diabetes Ther       Date:  2021-04-26       Impact factor: 2.945

7.  Barriers and facilitators to self-monitoring of blood glucose in people with type 2 diabetes using insulin: a qualitative study.

Authors:  Woon May Ong; Siew Siang Chua; Chirk Jenn Ng
Journal:  Patient Prefer Adherence       Date:  2014-02-15       Impact factor: 2.711

8.  Self-Monitoring of Blood Glucose and Hypoglycemia Association During Fasting in Ramadan Among Patients with Diabetes.

Authors:  Deyaa Mansouri; Ebtehal Khayat; Mohannad Khayat; Muteb Aboawja; Areej Aseeri; Faisal Banah; Khulood Alsiary; Lama Abdulaziz Rammal; Adel D Almalki; Mohammed Hasaballah
Journal:  Diabetes Metab Syndr Obes       Date:  2020-04-05       Impact factor: 3.168

  8 in total