Literature DB >> 18827699

Dynamic angular three-dimensional measurement of multisegmental thoracolumbar motion in vivo.

Erol Gercek1, Frank Hartmann, Sebastian Kuhn, Jurgen Degreif, Pol Maria Rommens, Lothar Rudig.   

Abstract

STUDY
DESIGN: Method validation and in vivo motion segment study.
OBJECTIVE: To determine in healthy subjects in vivo intervertebral segmental kinematics and coupled motion behavior in all 3 planes simultaneously for 3 segments and to evaluate whether these results differ from those in the normal population according to the literature. SUMMARY OF BACKGROUND DATA: Few studies have provided a direct invasive approach to investigate segmental kinematics in vivo. Dynamic recordings of 3-dimensional segmental motion patterns of adjacent segments have rarely been reported. To date, no studies have examined the 3-dimensional segmental movements of the thoracolumbar junction in vivo in detail.
METHODS: K-wires were inserted into the Th11, Th12, L1, and L2 spinous processes of 21 healthy subjects. Ultrasound markers and sensors were attached to the k-wires. Real-time motion data were recorded during standardized ranging exercises. Errors caused by the k-wires, and the static and dynamic accuracy of the system, were considered.
RESULTS: Large intersubject variation was found in all of the exercises. The average ranges of motion from Th11 to L2 were 18.7 degrees for flexion-extension, 13.5 degrees for one-sided lateral bending, and 1.8 degrees for one-sided axial rotation. Coupled-motion patterns among the subjects showed a coupled flexion in active lateral bending and a coupled extension in active rotation, but the results were inconsistent for active extension and flexion.
CONCLUSION: This method offered accurate multisegmental dynamic-recording facilities. The dynamic exercises showed high reproducibility. The ranges of motion for extension/flexion and lateral bending differed from those reported in previous studies. The coupling patterns were only partly consistent because of large interindividual variation. The measurement error was comparable with that of other invasive methods.

Entities:  

Mesh:

Year:  2008        PMID: 18827699     DOI: 10.1097/BRS.0b013e31818096ea

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  2 in total

1.  Diffuse idiopathic skeletal hyperostosis (DISH) is a risk factor for further surgery in short-segment lumbar interbody fusion.

Authors:  Bungo Otsuki; Shunsuke Fujibayashi; Mitsuru Takemoto; Hiroaki Kimura; Takayoshi Shimizu; Shuichi Matsuda
Journal:  Eur Spine J       Date:  2014-10-01       Impact factor: 3.134

2.  Kinetic magnetic resonance imaging analysis of thoracolumbar segmental mobility in patients without significant spondylosis.

Authors:  Xingwang Yao; Fei Chen; Chuning Dong; Jeffrey Wang; Yanlin Tan
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.817

  2 in total