Literature DB >> 18827453

Correlation between high field MR images and histopathological findings of rat transplanted cancer immediately after partial microwave coagulation.

Koichiro Murakami1, Shigehiro Morikawa, Shigeyuki Naka, Koichi Demura, Koichiro Sato, Hisanori Shiomi, Yoshimasa Kurumi, Toshiro Inubushi, Tohru Tani.   

Abstract

PURPOSE: To investigate the immediate effects of microwave coagulation on rat tumors in various magnetic resonance (MR) images at high magnetic field strength using histopathological examinations as reference.
MATERIALS AND METHODS: Tumors implanted in rat femurs were partially thermocoagulated by microwave. Immediately after, T1- and T2-weighted images, diffusion-weighted images (DWIs), and contrast-enhanced T1 weighted images (CE-T1WIs) were acquired with a 7-tesla MR scanner. After measurements, tumors were examined histopathologically with hematoxylin-eosin (HE) staining and histochemically for acid phosphatase activity.
RESULTS: Without contrast, boundaries of coagulated areas were unclear on MR images, including apparent diffusion coefficient (ADC) maps. CE-T1WIs clearly showed immediate contrast enhancement of untreated areas of tumor, and the area of enhancement gradually enlarged in 5 min. Quantitative analyses were conducted by classifying tumor areas by contrast enhancement results. Signal intensities of the areas in the MR images showed no significant differences, but at the periphery, ADC values were significantly higher in areas with delayed enhancement than those with immediate enhancement. Compared with histopathological findings, with microwave thermocoagulation, increased ADC value seemed to derive from collection of extracellular fluid in the outer zone, where acid phosphatase activity was attenuated.
CONCLUSION: ADC values in the areas with delayed enhancement of CE-T1WIs were higher than those in non-affected areas, but MR images could not show areas of coagulation within tumors. Clear detection of the boundaries of coagulated areas required contrast enhancement, even at magnetic field strength of 7T.

Entities:  

Mesh:

Year:  2008        PMID: 18827453     DOI: 10.2463/mrms.7.105

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


  3 in total

1.  Initial experiences with MR Image-guided laparoscopic microwave coagulation therapy for hepatic tumors.

Authors:  Koichiro Murakami; Shigeyuki Naka; Hisanori Shiomi; Hiroya Akabori; Yoshimasa Kurumi; Shigehiro Morikawa; Tohru Tani
Journal:  Surg Today       Date:  2014-10-09       Impact factor: 2.549

2.  A micro-imaging study linking bone cancer pain with tumor growth and bone resorption in a rat model.

Authors:  Louis Doré-Savard; Nicolas Beaudet; Luc Tremblay; Yongjun Xiao; Martin Lepage; Philippe Sarret
Journal:  Clin Exp Metastasis       Date:  2012-09-06       Impact factor: 5.150

3.  Relating Doses of Contrast Agent Administered to TIC and Semi-Quantitative Parameters on DCE-MRI: Based on a Murine Breast Tumor Model.

Authors:  Menglin Wu; Li Lu; Qi Zhang; Qi Guo; Feixiang Zhao; Tongwei Li; Xuening Zhang
Journal:  PLoS One       Date:  2016-02-22       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.