Literature DB >> 18827316

Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms.

Peter J Dimbylow1, Akimasa Hirata, Tomoaki Nagaoka.   

Abstract

This paper provides an intercomparison of the HPA male and female models, NORMAN and NAOMI with the National Institute of Information and Communications Technology (NICT) male and female models, TARO and HANAKO. The calculations of the whole-body SAR in these four phantoms were performed at the HPA, at NICT and at the Nagoya Institute of Technology (NIT). These were for a plane wave with a vertically aligned electric field incident upon the front of the body from 30 MHz to 3 GHz for isolated conditions. As well as investigating the general differences through this frequency range, particular emphasis was placed on the assumptions of how dielectric properties are assigned to tissues (particularly skin and fat) and the consequence of using different algorithms for calculating SAR at the higher frequencies.

Entities:  

Mesh:

Year:  2008        PMID: 18827316     DOI: 10.1088/0031-9155/53/20/022

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609