Literature DB >> 18826246

Laser ablation coupled to a flowing atmospheric pressure afterglow for ambient mass spectral imaging.

Jacob T Shelley1, Steven J Ray, Gary M Hieftje.   

Abstract

A plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) source was used to perform molecular mass spectral imaging. A small amount of sample material was ablated by focusing 266 nm laser light onto a spot. The resulting aerosol was transferred by a nitrogen stream to the flowing afterglow of a helium atmospheric pressure glow discharge ionization source; the ionized sample material was analyzed by a Leco Unique time-of-flight mass spectrometer. Two-dimensional mass spectral images were generated by scanning the laser beam across a sample surface. The total analysis time for a 6 mm (2) surface, which is limited by the washout of the ablation chamber, was less than 30 min. With this technique, a spatial resolution of approximately 20 microm has been achieved. Additionally, the laser ablation configuration was used to obtain depth information of over 2 mm with a resolution of approximately 40 microm. The combination of laser ablation with the flowing atmospheric pressure afterglow source was used to analyze several sample surfaces for a wide variety of analytes and with high sensitivity (LOD of 5 fmol for caffeine).

Entities:  

Mesh:

Year:  2008        PMID: 18826246     DOI: 10.1021/ac801594u

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  15 in total

1.  Data processing for 3D mass spectrometry imaging.

Authors:  Xingchuang Xiong; Wei Xu; Livia S Eberlin; Justin M Wiseman; Xiang Fang; You Jiang; Zejian Huang; Yukui Zhang; R Graham Cooks; Zheng Ouyang
Journal:  J Am Soc Mass Spectrom       Date:  2012-03-03       Impact factor: 3.109

2.  Distinctive glycerophospholipid profiles of human seminoma and adjacent normal tissues by desorption electrospray ionization imaging mass spectrometry.

Authors:  Timothy A Masterson; Allison L Dill; Livia S Eberlin; Monica Mattarozzi; Liang Cheng; Stephen D W Beck; Federica Bianchi; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2011-04-26       Impact factor: 3.109

3.  Multimodal Vacuum-Assisted Plasma Ion (VaPI) Source with Transmission Mode and Laser Ablation Sampling Capabilities.

Authors:  Joel D Keelor; Paul B Farnsworth; Arthur L Weber; Heather Abbott-Lyon; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-16       Impact factor: 3.109

Review 4.  What can we learn from ambient ionization techniques?

Authors:  Huanwen Chen; Gerardo Gamez; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2009-08-13       Impact factor: 3.109

5.  Detection of positive and negative ions from a flowing atmospheric pressure afterglow using a Mattauch-Herzog mass spectrograph equipped with a Faraday-strip array detector.

Authors:  Gregory D Schilling; Jacob T Shelley; James H Barnes; Roger P Sperline; M Bonner Denton; Charles J Barinaga; David W Koppenaal; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-20       Impact factor: 3.109

6.  Halo-shaped flowing atmospheric pressure afterglow: a heavenly design for simplified sample introduction and improved ionization in ambient mass spectrometry.

Authors:  Kevin P Pfeuffer; J Niklas Schaper; Jacob T Shelley; Steven J Ray; George C-Y Chan; Nicolas H Bings; Gary M Hieftje
Journal:  Anal Chem       Date:  2013-07-15       Impact factor: 6.986

Review 7.  Desorption electrospray ionization mass spectrometry for lipid characterization and biological tissue imaging.

Authors:  Livia S Eberlin; Christina R Ferreira; Allison L Dill; Demian R Ifa; R Graham Cooks
Journal:  Biochim Biophys Acta       Date:  2011-05-27

Review 8.  Mass spectrometry imaging under ambient conditions.

Authors:  Chunping Wu; Allison L Dill; Livia S Eberlin; R Graham Cooks; Demian R Ifa
Journal:  Mass Spectrom Rev       Date:  2012-09-20       Impact factor: 10.946

9.  Ultrasensitive ambient mass spectrometric analysis with a pin-to-capillary flowing atmospheric-pressure afterglow source.

Authors:  Jacob T Shelley; Joshua S Wiley; Gary M Hieftje
Journal:  Anal Chem       Date:  2011-06-16       Impact factor: 6.986

Review 10.  High resolution laser mass spectrometry bioimaging.

Authors:  Kermit K Murray; Chinthaka A Seneviratne; Suman Ghorai
Journal:  Methods       Date:  2016-03-10       Impact factor: 3.608

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.