Literature DB >> 18823769

Early determination of cystic fibrosis by electrochemical chloride quantification in sweat.

Javier Gonzalo-Ruiz1, Roser Mas, Carmen de Haro, Enric Cabruja, Rafael Camero, M Asuncion Alonso-Lomillo, F Javier Muñoz.   

Abstract

A novel and rapid approach to quantify chloride concentration in sweat for early detection of cystic fibrosis (CF) is shown in this work. Disposable screen-printed sensor (SPS) devices capable to induce sweat and measure the chloride concentration are presented. Pilocarpine, which was forced into de skin by means of iontophoresis, has been used to stimulate the sweat glands. Chloride concentration has been directly measured on the skin by potentiometry. The performance of the devices has been tested in synthetic samples, obtaining good agreement with the Nernst equation. Sensors reproducibility has been analyzed in terms of residual standard deviation (RSD), obtaining a value of 8% (n=6 and alpha=0.05). Finally, the application of these sensors in several volunteers has been carried out. The results were compared with the method generally used in hospitals, obtaining deviations minor than 8%.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18823769     DOI: 10.1016/j.bios.2008.07.051

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  13 in total

1.  Colorimetric sensing of chloride in sweat based on fluorescence wavelength shift via halide exchange of CsPbBr3 perovskite nanocrystals.

Authors:  Feiming Li; Yufeng Feng; Yipeng Huang; Qiuhong Yao; Guihua Huang; Yimeng Zhu; Xi Chen
Journal:  Mikrochim Acta       Date:  2021-01-02       Impact factor: 5.833

2.  Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform.

Authors:  Sam Emaminejad; Wei Gao; Eric Wu; Zoe A Davies; Hnin Yin Yin Nyein; Samyuktha Challa; Sean P Ryan; Hossain M Fahad; Kevin Chen; Ziba Shahpar; Salmonn Talebi; Carlos Milla; Ali Javey; Ronald W Davis
Journal:  Proc Natl Acad Sci U S A       Date:  2017-04-17       Impact factor: 11.205

3.  A fully screen-printed potentiometric chloride ion sensor employing a hydrogel-based touchpad for simple and non-invasive daily electrolyte analysis.

Authors:  Yusuke Ichimura; Takumi Kuritsubo; Kuniaki Nagamine; Ayako Nomura; Isao Shitanda; Shizuo Tokito
Journal:  Anal Bioanal Chem       Date:  2021-01-22       Impact factor: 4.142

4.  Silver-manganese nanocomposite modified screen-printed carbon electrode in the fabrication of an electrochemical, disposable biosensor strip for cystic fibrosis.

Authors:  P Arun Kumar; Aarathi Pradeep; Bipin Kumar G Nair; T G Satheesh Babu; Punathil Vasu Suneesh
Journal:  Mikrochim Acta       Date:  2022-08-11       Impact factor: 6.408

5.  Chemical sensor platform for non-invasive monitoring of activity and dehydration.

Authors:  Dmitry Solovei; Jaromír Žák; Petra Majzlíková; Jiří Sedláček; Jaromír Hubálek
Journal:  Sensors (Basel)       Date:  2015-01-14       Impact factor: 3.576

6.  Towards Addressing the Body Electrolyte Environment via Sweat Analysis:Pilocarpine Iontophoresis Supports Assessment of Plasma Potassium Concentration.

Authors:  Donato Vairo; Laurie Bruzzese; Marion Marlinge; Lea Fuster; Nabil Adjriou; Nathalie Kipson; Philippe Brunet; Jennifer Cautela; Yves Jammes; Giovanna Mottola; Stephane Burtey; Jean Ruf; Regis Guieu; Emmanuel Fenouillet
Journal:  Sci Rep       Date:  2017-09-18       Impact factor: 4.379

Review 7.  Electronic Tongue-A Tool for All Tastes?

Authors:  Marta Podrażka; Ewa Bączyńska; Magdalena Kundys; Paulina S Jeleń; Emilia Witkowska Nery
Journal:  Biosensors (Basel)       Date:  2017-12-31

8.  Smartphone-Based pH Sensor for Home Monitoring of Pulmonary Exacerbations in Cystic Fibrosis.

Authors:  Alexander Sun; Tom Phelps; Chengyang Yao; A G Venkatesh; Douglas Conrad; Drew A Hall
Journal:  Sensors (Basel)       Date:  2017-05-30       Impact factor: 3.576

9.  Chemically modified hCFTR mRNAs recuperate lung function in a mouse model of cystic fibrosis.

Authors:  A K M Ashiqul Haque; Alexander Dewerth; Justin S Antony; Joachim Riethmüller; Georg R Schweizer; Petra Weinmann; Ngadhnjim Latifi; Hanzey Yasar; Nicoletta Pedemonte; Elvira Sondo; Brian Weidensee; Anjali Ralhan; Julie Laval; Patrick Schlegel; Christian Seitz; Brigitta Loretz; Claus-Michael Lehr; Rupert Handgretinger; Michael S D Kormann
Journal:  Sci Rep       Date:  2018-11-13       Impact factor: 4.379

Review 10.  Integration of biosensors and drug delivery technologies for early detection and chronic management of illness.

Authors:  Mpho Ngoepe; Yahya E Choonara; Charu Tyagi; Lomas Kumar Tomar; Lisa C du Toit; Pradeep Kumar; Valence M K Ndesendo; Viness Pillay
Journal:  Sensors (Basel)       Date:  2013-06-14       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.