Literature DB >> 18823768

Electrically active polyaniline coated magnetic (EAPM) nanoparticle as novel transducer in biosensor for detection of Bacillus anthracis spores in food samples.

Sudeshna Pal1, Evangelyn C Alocilja.   

Abstract

Electrically active polyaniline coated magnetic (EAPM) nanoparticle-based biosensor has been developed for the detection of Bacillus anthracis endospores in contaminated food samples. The 100 nm-diameter EAPM nanoparticles are synthesized from aniline monomer (made electrically active by acid doping) coating the surface of gamma iron oxide cores. The magnetic, electrical, and structural characteristics of the synthesized EAPM nanoparticles have been studied using superconducting quantum interference device (SQUID), four-point probe, and transmission electron microscopy (TEM). Room temperature hysteresis of the synthesized nanoparticles shows a saturation magnetization value of 44.1 emu/g. The EAPM nanoparticles are biologically modified to act as an immunomagnetic concentrator of B. anthracis spores from lettuce, ground beef and whole milk samples and are directly applied to a direct-charge transfer biosensor. The detection mechanism of the biosensor depends on the capillary flow of the captured spores on the biosensor surface along with direct-charge transfer across the EAPM nanoparticles. Experimental results indicate that the biosensor is able to detect B. anthracis spores at concentrations as low as 4.2 x 10(2)spores/ml from the samples. The EAPM-based biosensor detection system is fast and reliable with a total detection time of 16 min.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18823768     DOI: 10.1016/j.bios.2008.08.020

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  8 in total

Review 1.  Electrochemical biosensors for pathogen detection.

Authors:  Ellen Cesewski; Blake N Johnson
Journal:  Biosens Bioelectron       Date:  2020-04-12       Impact factor: 10.618

Review 2.  Industrial applications of immobilized nano-biocatalysts.

Authors:  Mozhgan Razzaghi; Ahmad Homaei; Fabio Vianello; Taha Azad; Tanvi Sharma; Ashok Kumar Nadda; Roberto Stevanato; Muhammad Bilal; Hafiz M N Iqbal
Journal:  Bioprocess Biosyst Eng       Date:  2021-10-01       Impact factor: 3.210

3.  Gold nanoparticle-labeled biosensor for rapid and sensitive detection of bacterial pathogens.

Authors:  Yun Wang; Evangelyn C Alocilja
Journal:  J Biol Eng       Date:  2015-10-02       Impact factor: 4.355

4.  Optimization of electrically active magnetic nanoparticles as accurate and efficient microbial extraction tools.

Authors:  Barbara C Cloutier; Ashley K Cloutier; Evangelyn C Alocilja
Journal:  Biosensors (Basel)       Date:  2015-02-05

5.  Electrochemical biosensor for rapid and sensitive detection of magnetically extracted bacterial pathogens.

Authors:  Emma B Setterington; Evangelyn C Alocilja
Journal:  Biosensors (Basel)       Date:  2012-01-17

6.  Rapid Detection of Bacillus anthracis Spores Using Immunomagnetic Separation and Amperometry.

Authors:  David F Waller; Brian E Hew; Charlie Holdaway; Michael Jen; Gabriel D Peckham
Journal:  Biosensors (Basel)       Date:  2016-12-20

7.  Detection of non-PCR amplified S. enteritidis genomic DNA from food matrices using a gold-nanoparticle DNA biosensor: a proof-of-concept study.

Authors:  Sylvia A Vetrone; Michael C Huarng; Evangelyn C Alocilja
Journal:  Sensors (Basel)       Date:  2012-08-02       Impact factor: 3.576

Review 8.  Nanomaterial-based biosensors for detection of pathogenic virus.

Authors:  Ahad Mokhtarzadeh; Reza Eivazzadeh-Keihan; Paria Pashazadeh; Maryam Hejazi; Nasrin Gharaatifar; Mohammad Hasanzadeh; Behzad Baradaran; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2017-10-13       Impact factor: 12.296

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.