Literature DB >> 18819119

A high-resolution scanning microprobe matrix-assisted laser desorption/ionization ion source for imaging analysis on an ion trap/Fourier transform ion cyclotron resonance mass spectrometer.

Martin Koestler1, Dieter Kirsch, Alfons Hester, Arne Leisner, Sabine Guenther, Bernhard Spengler.   

Abstract

A new scanning microprobe matrix-assisted laser desorption/ionization (SMALDI) ion source for high spatial resolution has been developed for linear ion trap and Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). The source is fully compatible with commercial ion trap flanges (such as the LTQ series, Thermo Fisher Scientific). The source is designed for atmospheric pressure (AP) operation but is also suitable for mid-pressure operation. The AP mode is especially useful for investigating volatile compounds. The source can be interchanged with other ion sources within a minute when operated in the AP mode. Combining high-lateral resolution MALDI imaging with high mass resolution and high mass accuracy mass spectrometry, available in the FT-ICR mode, provides a new quality of analytical information, e.g. from biological samples. First results obtained with the new ion source demonstrate a maximum lateral resolution of 0.6 by 0.5 microm. Depending on the limit of detection of the chosen mass analyzer, however, the size of the focus had to be enlarged to a diameter of up to 8 microm in the FT-ICR mode, in order to create enough ions for detection. Mass spectra acquired for analytical imaging were obtained from single laser pulses per pixel in all the experiments. This mode allows us to investigate biological thin sections with desorption focus diameters in the micrometer range, known to cause complete evaporation of material under the laser focus with a very limited number of laser pulses. As a first example, peptide samples deposited in microstructures were investigated with the new setup. A high quality and validity of the acquired images were obtained in the ion trap mode due to the low limit of detection. High mass resolution and accuracy but poorer image quality were obtained in the ICR mode due to the lower detection sensitivity of the ICR detector.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18819119     DOI: 10.1002/rcm.3733

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  36 in total

1.  Fast, high resolution mass spectrometry imaging using a Medipix pixelated detector.

Authors:  Julia H Jungmann; Luke MacAleese; Ronald Buijs; Frans Giskes; Ad de Snaijer; Jan Visser; Jan Visschers; Marc J J Vrakking; Ron M A Heeren
Journal:  J Am Soc Mass Spectrom       Date:  2010-08-27       Impact factor: 3.109

2.  Revisiting rat spermatogenesis with MALDI imaging at 20-microm resolution.

Authors:  Mélanie Lagarrigue; Michael Becker; Régis Lavigne; Sören-Oliver Deininger; Axel Walch; Florence Aubry; Detlev Suckau; Charles Pineau
Journal:  Mol Cell Proteomics       Date:  2010-12-12       Impact factor: 5.911

3.  Analytical challenges of shotgun lipidomics at different resolution of measurements.

Authors:  Jianing Wang; Xianlin Han
Journal:  Trends Analyt Chem       Date:  2019-10-17       Impact factor: 12.296

4.  Mirion--a software package for automatic processing of mass spectrometric images.

Authors:  C Paschke; A Leisner; A Hester; K Maass; S Guenther; W Bouschen; B Spengler
Journal:  J Am Soc Mass Spectrom       Date:  2013-06-13       Impact factor: 3.109

5.  A high resolution atmospheric pressure matrix-assisted laser desorption/ionization-quadrupole-orbitrap MS platform enables in situ analysis of biomolecules by multi-mode ionization and acquisition.

Authors:  Bingming Chen; Chuanzi OuYang; Zichuan Tian; Meng Xu; Lingjun Li
Journal:  Anal Chim Acta       Date:  2018-01-06       Impact factor: 6.558

6.  High-speed tandem mass spectrometric in situ imaging by nanospray desorption electrospray ionization mass spectrometry.

Authors:  Ingela Lanekoff; Kristin Burnum-Johnson; Mathew Thomas; Joshua Short; James P Carson; Jeeyeon Cha; Sudhansu K Dey; Pengxiang Yang; Maria C Prieto Conaway; Julia Laskin
Journal:  Anal Chem       Date:  2013-10-03       Impact factor: 6.986

7.  Cellular-level mass spectrometry imaging using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) by oversampling.

Authors:  Milad Nazari; David C Muddiman
Journal:  Anal Bioanal Chem       Date:  2014-12-09       Impact factor: 4.142

Review 8.  Matrix-assisted laser desorption ionization imaging mass spectrometry: in situ molecular mapping.

Authors:  Peggi M Angel; Richard M Caprioli
Journal:  Biochemistry       Date:  2013-01-16       Impact factor: 3.162

9.  para-Nitroaniline is a promising matrix for MALDI-MS imaging on intermediate pressure MS systems.

Authors:  Rory T Steven; Alan M Race; Josephine Bunch
Journal:  J Am Soc Mass Spectrom       Date:  2013-03-02       Impact factor: 3.109

10.  Detection of carbohydrates and steroids by cation-enhanced nanostructure-initiator mass spectrometry (NIMS) for biofluid analysis and tissue imaging.

Authors:  Gary J Patti; Hin-Koon Woo; Oscar Yanes; Leah Shriver; Diane Thomas; Wilasinee Uritboonthai; Junefredo V Apon; Rick Steenwyk; Marianne Manchester; Gary Siuzdak
Journal:  Anal Chem       Date:  2010-01-01       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.