Literature DB >> 18819113

Development and validation of an analytical method for the simultaneous determination of cocaine and its main metabolite, benzoylecgonine, in human hair by gas chromatography/mass spectrometry.

M Barroso1, M Dias, D N Vieira, J A Queiroz, M López-Rivadulla.   

Abstract

A new, simple and rapid procedure has been developed and validated for the determination of cocaine and its main metabolite, benzoylecgonine, in human hair samples. After extraction from within the hair matrix by a mixture of methanol/hydrochloric acid (2:1) at 65 degrees C for 3 h, and sample cleanup by mixed-mode solid-phase extraction (SPE), the extracts were analyzed by gas chromatography/mass spectrometry (GC/MS), after derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide with 5% chlorotrimethylsilane. Using a sample size of only 20 mg of hair, limits of detection (LODs) and quantitation (LOQs) were, respectively, 20 and 50 pg/mg for cocaine, and 15 and 50 pg/mg for benzoylecgonine, achieving the cut-off values proposed by the Society of Hair Testing for the analysis of these compounds in hair. The method was found to be linear (weighing factor of 1/x) between the LOQ and 20 ng/mg for both compounds, with correlation coefficients ranging from 0.9974 to 0.9996 for cocaine; and from 0.9981 to 0.9994 for benzoylecgonine. Intra- and interday precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The sample cleanup step presented a mean absolute recovery greater than 90% for both compounds. The developed method may be useful in forensic toxicology laboratories for the analysis of cocaine and benzoylecgonine in hair samples, taking into account its speed (only 3 h are required for the extraction of the analytes from within the matrix, whereas 5 h or even overnight extractions have been reported) and the low limits achieved (using a single quadrupole mass spectrometer, which is available in most laboratories).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18819113     DOI: 10.1002/rcm.3738

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Degradation of UV-filter Benzophenon-3 in aqueous solution using TiO2 coated on quartz tubes.

Authors:  Nazanin Moradi; Mohammad Mehdi Amin; Ali Fatehizadeh; Zahra Ghasemi
Journal:  J Environ Health Sci Eng       Date:  2018-08-15

2.  Aptamer-based cocaine assay using a nanohybrid composed of ZnS/Ag2Se quantum dots, graphene oxide and gold nanoparticles as a fluorescent probe.

Authors:  Oluwasesan Adegoke; Magda A Pereira-Barros; Svetlana Zolotovskaya; Amin Abdolvand; Niamh Nic Daeid
Journal:  Mikrochim Acta       Date:  2020-01-08       Impact factor: 5.833

Review 3.  Cocaine: An Updated Overview on Chemistry, Detection, Biokinetics, and Pharmacotoxicological Aspects including Abuse Pattern.

Authors:  Rita Roque Bravo; Ana Carolina Faria; Andreia Machado Brito-da-Costa; Helena Carmo; Přemysl Mladěnka; Diana Dias da Silva; Fernando Remião
Journal:  Toxins (Basel)       Date:  2022-04-13       Impact factor: 5.075

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.