| Literature DB >> 18816820 |
Robert Stobbe1, Christian Beaulieu.
Abstract
For sodium imaging of the human brain, Gibbs' ringing can degrade image appearance and confound image analysis; k-space filtering is generally required. In this work, the signal to noise ratio (SNR) advantage of sampling density weighted apodization (SDWA) over uniform k-space sampling with postacquisition filtering apodization (UPFA) is quantified for sodium three-dimensional (3D) twisted projection imaging (TPI) of the human brain. A direct comparison was conducted with the creation of two TPI projection data sets (each with an equal number of projections of equal length): one generating uniform sampling density, and the other a "generalized Hamming" sampling density that conformed to 3D-TPI constraints for full k-space sampling. In this work it is shown theoretically, and then experimentally with sodium imaging of the human brain, that an SNR advantage of 17% is associated with the use of SDWA over UPFA for the filter presented, along with a significant noise-coloring benefit. (c) 2008 Wiley-Liss, Inc.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18816820 DOI: 10.1002/mrm.21738