Literature DB >> 18816811

Exponential excitation pulses for improved water content mapping in the presence of background gradients.

Christine Preibisch1, Steffen Volz, Sandra Anti, Ralf Deichmann.   

Abstract

Several water content mapping techniques are based on the acquisition of multiple gradient echoes (GE) with different echo times (TE). However, in the presence of linear magnetic field gradients G(susc) the signal decay is no longer exponential but in the case of a rectangular slice profile weighted by a sinc function, giving rise to erroneous initial amplitudes S(0) in monoexponential fitting. Generally, it can be shown that the signal decay is weighted by the time profile of the excitation pulse. Thus, for an excitation pulse with an exponential time profile, i.e., a Lorentzian slice profile, the signal decay remains exponential and exponential fitting still yields the correct amplitude S(0). Multiecho GE images of a gel phantom and five human volunteers were acquired at 3 T using a sinc-shaped and an exponential excitation pulse. In addition, simulations were performed to investigate the influence of saturation effects due to distortion of the ideal Lorentzian slice profile. A considerable overestimation of S(0) when using a sinc-shaped excitation pulse was observed. Errors were greatly reduced with an exponential excitation pulse. We thus propose the use of excitation pulses with exponential time profile to obtain accurate estimates for S(0) from exponential fitting. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18816811     DOI: 10.1002/mrm.21730

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  T2* mapping with background gradient correction using different excitation pulse shapes.

Authors:  N M Hirsch; C Preibisch
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-26       Impact factor: 3.825

2.  Recurrence of glioblastoma is associated with elevated microvascular transit time heterogeneity and increased hypoxia.

Authors:  Andreas Stadlbauer; Kim Mouridsen; Arnd Doerfler; Mikkel Bo Hansen; Stefan Oberndorfer; Max Zimmermann; Michael Buchfelder; Gertraud Heinz; Karl Roessler
Journal:  J Cereb Blood Flow Metab       Date:  2017-02-24       Impact factor: 6.200

3.  Development of a Non-invasive Assessment of Hypoxia and Neovascularization with Magnetic Resonance Imaging in Benign and Malignant Breast Tumors: Initial Results.

Authors:  Andreas Stadlbauer; Max Zimmermann; Barbara Bennani-Baiti; Thomas H Helbich; Pascal Baltzer; Paola Clauser; Panagiotis Kapetas; Zsuzsanna Bago-Horvath; Katja Pinker
Journal:  Mol Imaging Biol       Date:  2019-08       Impact factor: 3.488

4.  Radiophysiomics: Brain Tumors Classification by Machine Learning and Physiological MRI Data.

Authors:  Andreas Stadlbauer; Franz Marhold; Stefan Oberndorfer; Gertraud Heinz; Michael Buchfelder; Thomas M Kinfe; Anke Meyer-Bäse
Journal:  Cancers (Basel)       Date:  2022-05-10       Impact factor: 6.575

5.  T2* Relaxometry in Patients with Parkinson's Disease : Use of an Automated Atlas-based Approach.

Authors:  Karl Egger; Florian Amtage; Shan Yang; Markus Obmann; Ralf Schwarzwald; Lena Köstering; Irina Mader; Julia Koenigsdorf; Cornelius Weiller; Christoph P Kaller; Horst Urbach
Journal:  Clin Neuroradiol       Date:  2016-06-22       Impact factor: 3.649

6.  Intratumoral heterogeneity of oxygen metabolism and neovascularization uncovers 2 survival-relevant subgroups of IDH1 wild-type glioblastoma.

Authors:  Andreas Stadlbauer; Max Zimmermann; Arnd Doerfler; Stefan Oberndorfer; Michael Buchfelder; Roland Coras; Melitta Kitzwögerer; Karl Roessler
Journal:  Neuro Oncol       Date:  2018-10-09       Impact factor: 12.300

7.  Adaptive slice-specific z-shimming for 2D spoiled gradient-echo sequences.

Authors:  Martin Soellradl; Johannes Strasser; Andreas Lesch; Rudolf Stollberger; Stefan Ropele; Christian Langkammer
Journal:  Magn Reson Med       Date:  2020-09-10       Impact factor: 4.668

8.  A 3D two-point method for whole-brain water content and relaxation time mapping: Comparison with gold standard methods.

Authors:  Melissa Schall; Markus Zimmermann; Elene Iordanishvili; Yun Gu; N Jon Shah; Ana-Maria Oros-Peusquens
Journal:  PLoS One       Date:  2018-08-30       Impact factor: 3.240

9.  Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

Authors:  Martin Soellradl; Andreas Lesch; Johannes Strasser; Lukas Pirpamer; Rudolf Stollberger; Stefan Ropele; Christian Langkammer
Journal:  Magn Reson Med       Date:  2019-12-23       Impact factor: 4.668

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.