Usefulness of multidetector CT imaging to assess vascular stents in children with congenital heart disease: an in vivo and in vitro study.

Joachim G Eichhorn1, Frederick R Long, Claudia Jourdan, Johannes T Heverhagen, Sharon L Hill, Subha V Raman, John P Cheatham.   

Abstract

OBJECTIVE: To evaluate varying CT settings to visualize pediatric vascular stents in comparison to digital angiography (DA).
BACKGROUND: There is a great clinical interest in substituting noninvasive methods to follow up children with congenital heart disease after interventional treatment.
MATERIALS AND METHODS: CT studies in small children with transcatheter placed stents were reviewed, retrospectively. Furthermore, eight stents were implanted in tubes and partially obstructed. CT exams were performed on varying scanners (4 up to 64 slices) with corresponding tube settings. The effects of dose on image quality were evaluated regarding stent size, strut thickness, and in-stent stenoses in comparison to DA.
RESULTS: Fourteen children with 28 implanted stents were identified. Significant differences between higher and lower radiation settings were not found, corresponding with the phantom, where moderate tube setting showed the best results. In vitro, there was an improvement with increasing number of detector rows, which resulted in a decrease of stent strut overestimation (295% down to 201%; P < 0.0001) and a better agreement with DA measurements for mild (78% up to 91%; P = 0.003) and moderate in-stent stenoses (80% up to 99%; P = 0.0001).
CONCLUSION: Higher radiation exposure settings did not improve image quality, suggesting that the exams could be performed at a lower radiation dose. 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18814228     DOI: 10.1002/ccd.21680

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

1.  Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents.

Authors:  Christian A Barrera; Hansel J Otero; Ammie M White; David Saul; David M Biko
Journal:  Int J Cardiovasc Imaging       Date:  2019-01-25       Impact factor: 2.357

2.  Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types.

Authors:  Michael Köhler; Matthias C Burg; Alexander C Bunck; Walter Heindel; Harald Seifarth; David Maintz
Journal:  Radiol Res Pract       Date:  2011-07-18

3.  Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?

Authors:  A M den Harder; D Suchá; R W van Hamersvelt; R P J Budde; P A de Jong; A M R Schilham; C Bos; J M P J Breur; T Leiner
Journal:  PLoS One       Date:  2017-01-31       Impact factor: 3.240

4.  Radiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study.

Authors:  Annemarie M den Harder; Dominika Suchá; Pieter J van Doormaal; Ricardo P J Budde; Pim A de Jong; Arnold M R Schilham; Johannes M P J Breur; Tim Leiner
Journal:  PLoS One       Date:  2017-04-14       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.