Literature DB >> 1881316

Studies of restricted diffusion in heterogeneous media containing variations in susceptibility.

J H Zhong1, J C Gore.   

Abstract

Measurements of water self-diffusion in heterogeneous media by pulsed gradient spin-echo methods depend on the precise choice of experimental parameters. This variation may reflect the presence of restricted or anisotropic diffusion, or the presence of intrinsic magnetic field gradients. In experiments at 2.0 T, restricted diffusion effects have been demonstrated in freshly excised tissues with an effective barrier radius of order 10 microns. In samples with intrinsic susceptibility variations such as tissues or gels containing dispersions of iron oxide particles, the reduction of apparent diffusion coefficient with diffusion interval can be used to estimate the degree of heterogeneity of the magnetic field in the sample. The implications of these effects for diffusion-weighted MRI as well as their use to derive novel tissue parameters are discussed.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1881316     DOI: 10.1002/mrm.1910190215

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Improved diffusion measurement in heterogeneous systems using the magic asymmetric gradient stimulated echo (MAGSTE) technique.

Authors:  Phillip Zhe Sun
Journal:  J Magn Reson       Date:  2007-04-27       Impact factor: 2.229

2.  Hybrid multidimensional T(2) and diffusion-weighted MRI for prostate cancer detection.

Authors:  Shiyang Wang; Yahui Peng; Milica Medved; Ambereen N Yousuf; Marko K Ivancevic; Ibrahim Karademir; Yulei Jiang; Tatjana Antic; Steffen Sammet; Aytekin Oto; Gregory S Karczmar
Journal:  J Magn Reson Imaging       Date:  2013-08-01       Impact factor: 4.813

Review 3.  Magnetic resonance in the era of molecular imaging of cancer.

Authors:  John C Gore; H Charles Manning; C Chad Quarles; Kevin W Waddell; Thomas E Yankeelov
Journal:  Magn Reson Imaging       Date:  2011-04-27       Impact factor: 2.546

4.  Iron deposition influences the measurement of water diffusion tensor in the human brain: a combined analysis of diffusion and iron-induced phase changes.

Authors:  Xiaojun Xu; Qidong Wang; Jianhui Zhong; Minming Zhang
Journal:  Neuroradiology       Date:  2015-08-26       Impact factor: 2.804

5.  Image quality assessment of automatic three-segment MR attenuation correction vs. CT attenuation correction.

Authors:  Sasan Partovi; Andres Kohan; Chiara Gaeta; Christian Rubbert; Jose L Vercher-Conejero; Robert S Jones; James K O'Donnell; Patrick Wojtylak; Peter Faulhaber
Journal:  Am J Nucl Med Mol Imaging       Date:  2013-04-09

6.  Concerning the matching of magnetic susceptibility differences for the compensation of background gradients in anisotropic diffusion fibre phantoms.

Authors:  Ezequiel Farrher; Johannes Lindemeyer; Farida Grinberg; Ana-Maria Oros-Peusquens; N Jon Shah
Journal:  PLoS One       Date:  2017-05-03       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.