Literature DB >> 18812277

Haemodynamics and acid-base equilibrium after cardiac surgery: comparison of rapidly degradable hydroxyethyl starch solutions and albumin.

T Niemi1, A Schramko, A Kuitunen, S Kukkonen, R Suojaranta-Ylinen.   

Abstract

BACKGROUND: Stable haemodynamics is often achieved by administration of colloids after cardiac surgery. We conducted a prospective, randomized, open-label study comparing haemodynamics and acid-base equilibrium after infusion of two rapidly degradable hydroxyethyl starch (HES) solutions or human albumin (HA) to cardiac surgical patients.
MATERIALS AND METHODS: 45 patients received a predetermined fixed dose of 15 ml kg(-1) of either 6% HES (mW 130 kDa, n = 15), 6% HES (MW 200 kDa, n = 15) or 4% HA (MW 69 kDa, n = 15) after on-pump cardiac surgery.
RESULTS: Left ventricular filling pressures assessed using pulmonary artery catheter responded similarly in all groups. mean (SD) cardiac index was higher in HES130 [3.5 l min(-1) m(-2) (0.7) ] and HES200 [3.5 l min(-1) m(-2) (0.5)] than in HA [2.8 l min(-1) m(-2) (0.6)] group after completion of infusion (P = 0.002) but no differences were detected at 2 and 18 hours. Oxygen delivery increased in both HES groups but not in HA group. After cessation of infusion base excess was the most negative in Ha group. At 2 hours mean (SD) base excess was higher in HES130 [0 (1.32)] than in HES200 [-1.32 (2.27) ] and HA [-2.3 (1.3)] group (P = 0.002, between the groups).
CONCLUSIONS: We conclude that the effect of albumin on cardiac performance is inferior than that of HES130 or HES200 in early postoperative phase after cardiac surgery. HES130 induces no alterations in acid-base equilibrium whereas a negative base excess was observed after HA infusion.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18812277     DOI: 10.1177/145749690809700310

Source DB:  PubMed          Journal:  Scand J Surg        ISSN: 1457-4969            Impact factor:   2.360


  13 in total

Review 1.  Hydroxyethyl starch for cardiovascular surgery: a systematic review of randomized controlled trials.

Authors:  Xue-Yin Shi; Zui Zou; Xing-Ying He; Hai-Tao Xu; Hong-Bin Yuan; Hu Liu
Journal:  Eur J Clin Pharmacol       Date:  2011-03-02       Impact factor: 2.953

Review 2.  Randomised trials of 6% tetrastarch (hydroxyethyl starch 130/0.4 or 0.42) for severe sepsis reporting mortality: systematic review and meta-analysis.

Authors:  Amit Patel; Umeer Waheed; Stephen J Brett
Journal:  Intensive Care Med       Date:  2013-02-22       Impact factor: 17.440

Review 3.  Colloid solutions for fluid resuscitation.

Authors:  Frances Bunn; Daksha Trivedi
Journal:  Cochrane Database Syst Rev       Date:  2012-07-11

Review 4.  Colloid solutions: a clinical update.

Authors:  Tomi T Niemi; Ryo Miyashita; Michiaki Yamakage
Journal:  J Anesth       Date:  2010-10-17       Impact factor: 2.078

5.  Postoperative Acute Kidney Injury and Blood Product Transfusion After Synthetic Colloid Use During Cardiac Surgery.

Authors:  Rajika Tobey; Hao Cheng; Mei Gao; Zhongmin Li; J Nilas Young; W Douglas Boyd; Fuhai Ji; Hong Liu
Journal:  J Cardiothorac Vasc Anesth       Date:  2016-12-28       Impact factor: 2.628

6.  Tetrastarch in cardiac surgery: error, confounding and bias in a meta-analysis of randomized trials.

Authors:  Roberta J Navickis; Gary R Haynes; Mahlon M Wilkes
Journal:  Crit Care       Date:  2015-04-22       Impact factor: 9.097

7.  The impact of hydroxyethyl starches in cardiac surgery: a meta-analysis.

Authors:  Matthias Jacob; Jean-Luc Fellahi; Daniel Chappell; Andrea Kurz
Journal:  Crit Care       Date:  2014-12-04       Impact factor: 9.097

Review 8.  Intravascular volume therapy in adults: Guidelines from the Association of the Scientific Medical Societies in Germany.

Authors:  Gernot Marx; Achim W Schindler; Christoph Mosch; Joerg Albers; Michael Bauer; Irmela Gnass; Carsten Hobohm; Uwe Janssens; Stefan Kluge; Peter Kranke; Tobias Maurer; Waltraut Merz; Edmund Neugebauer; Michael Quintel; Norbert Senninger; Hans-Joachim Trampisch; Christian Waydhas; Rene Wildenauer; Kai Zacharowski; Michaela Eikermann
Journal:  Eur J Anaesthesiol       Date:  2016-07       Impact factor: 4.330

9.  Comparison of the effects of gelatin, Ringer's solution and a modern hydroxyl ethyl starch solution after coronary artery bypass graft surgery.

Authors:  S M Alavi; B Baharvand Ahmadi; B Baharestani; T Babaei
Journal:  Cardiovasc J Afr       Date:  2012-09       Impact factor: 1.167

Review 10.  Effect of perioperative crystalloid or colloid fluid therapy on hemorrhage, coagulation competence, and outcome: A systematic review and stratified meta-analysis.

Authors:  Kirsten C Rasmussen; Niels H Secher; Tom Pedersen
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.