Literature DB >> 18809960

High-definition flow Doppler ultrasonographic technique to assess hepatic vasculature compared with color or power Doppler ultrasonography: preliminary experience.

Se Hyung Kim1, Jeong Min Lee, Young Jun Kim, Jae Young Lee, Joon Koo Han, Byung Ihn Choi.   

Abstract

OBJECTIVE: The purpose of this study was to introduce a new high-definition flow (HDF) Doppler technique and to compare its performance with those of color Doppler ultrasonography (CDU) and power Doppler ultrasonography (PDU) for assessment of hepatic vasculature in native and transplanted livers.
METHODS: High-definition flow was invented as a high-resolution bidirectional PDU technique. We obtained CDU, PDU, and HDF images of the hepatic artery (HA), portal vein (PV), and hepatic vein from 60 patients. They were divided into 2 groups: a liver transplantation group (group 1, n = 10) and a native liver group (group 2, n = 50). Two radiologists independently reviewed the cine images and graded them using a 4-point scale in terms of the clarity of the vessel margin and degree of depiction of the HA, flow filling, and flash artifacts. The degree of differentiation between the HA and PV was also evaluated. Flow directionality was recorded, and interobserver agreement was finally analyzed.
RESULTS: Moderate to almost perfect agreement was achieved between radiologists for all parameters of each ultrasonographic technique. High-definition flow was significantly superior to both CDU and PDU with respect to all analyzed items except the degree of flash artifacts (P < .05). With regard to flash artifacts, CDU was significantly better than either PDU or HDF. High-definition flow provided directional information, as did CDU.
CONCLUSIONS: The HDF technique provides better resolution for depicting hepatic vessels as well as their margins with less blooming compared with conventional Doppler ultrasonography in both native and transplanted liver. It also provides solid directional flow information. One point of concern, however, is the frequency of flash artifacts compared with that on CDU.

Entities:  

Mesh:

Year:  2008        PMID: 18809960     DOI: 10.7863/jum.2008.27.10.1491

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  3 in total

1.  Three-dimensional high-definition flow in the diagnosis of placental lakes.

Authors:  Eisuke Inubashiri; Keizou Deguchi; Kiyotaka Abe; Atushi Saitou; Yukio Watanabe; Noriyuki Akutagawa; Katumaru Kuroki; Masaki Sugawara; Nobuhiko Maeda
Journal:  J Med Ultrason (2001)       Date:  2014-03-28       Impact factor: 1.314

2.  OvAge: a new methodology to quantify ovarian reserve combining clinical, biochemical and 3D-ultrasonographic parameters.

Authors:  Roberta Venturella; Daniela Lico; Alessia Sarica; Maria Pia Falbo; Elio Gulletta; Michele Morelli; Errico Zupi; Gabriele Cevenini; Mario Cannataro; Fulvio Zullo
Journal:  J Ovarian Res       Date:  2015-04-08       Impact factor: 4.234

3.  4D Doppler Ultrasound in High Grade Serous Ovarian Cancer Vascularity Evaluation-Preliminary Study.

Authors:  Marek Jerzy Kudla; Michal Zikan; Daniela Fischerova; Mateusz Stolecki; Juan Luis Alcazar
Journal:  Diagnostics (Basel)       Date:  2021-03-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.