Literature DB >> 18807574

Immediate versus delayed loading of dental implants placed in fresh extraction sockets in the maxillary esthetic zone: a clinical comparative study.

Roberto Crespi1, Paolo Capparé, Enrico Gherlone, George E Romanos.   

Abstract

PURPOSE: The aim of this study was to report a clinical comparative assessment of crestal bone level change around single implants in fresh extraction sockets in the esthetic zone of the maxilla either immediately loaded or loaded after a delay.
MATERIALS AND METHODS: Forty patients were included in a prospective, randomized study. All patients required 1 tooth extraction (ie, 1 tooth with a hopeless prognosis) and were randomized into either the test group or the control group. Implants were positioned immediately after tooth extraction and were loaded immediately in the test group (20 implants) and after 3 months in the control group (20 implants). The implant site was prepared, with at least 4 mm of sound apical bone below the implant apex, and the coronal margin of the implant was placed at the buccal level of the bone crest. All implants were 13 mm long; 30 implants had a diameter of 5 mm, and 10 had a diameter of 3.75 mm. Radiographic examinations were made at baseline, at 6 months, and at 24 months. To compare the mean values between test and control group, a paired t test was performed (considered statistically significant at P < .05).
RESULTS: After a 24-month follow-up period, a cumulative survival rate of 100% was reported for all implants. The control group resulted in a mean mesial bone loss of 1.16 +/- 0.32 mm and a mean distal bone loss of 1.17 +/- 0.41 (mean bone loss, 1.16 +/- 0.51 mm). The test group resulted in a mesial bone loss of 0.93 +/- 0.51 mm and a distal bone loss of 1.1 +/- 0.27 mm (mean bone loss, 1.02 +/- 0.53 mm). No statistically significant difference between control and test groups (P > .05) was found.
CONCLUSION: The success rate and radiographic results of immediate restorations of dental implants placed in fresh extraction sockets were comparable to those obtained in delayed loading group.

Entities:  

Mesh:

Year:  2008        PMID: 18807574

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  15 in total

Review 1.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

2.  Immediate vs non-immediate loading post-extractive implants: a comparative study of implant stability quotient (ISQ).

Authors:  L Milillo; C Fiandaca; F Giannoulis; L Ottria; A Lucchese; F Silvestre; M Petruzzi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

Review 3.  Interventions for replacing missing teeth: different times for loading dental implants.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Hassan Maghaireh; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2013-03-28

4.  Peri-implant bone response following immediate implants placed in the esthetic zone and with immediate provisionalization--a case series study.

Authors:  Carolina Martin; Geninho Thomé; Ana Cláudia Moreira Melo; Flavia Noemy Gasparini Kiatake Fontão
Journal:  Oral Maxillofac Surg       Date:  2014-10-23

5.  A comparative analysis of periimplant bone levels of immediate and conventionally loaded implants.

Authors:  G K Thapliyal; V R Pawar
Journal:  Med J Armed Forces India       Date:  2012-09-14

Review 6.  Immediate implants following tooth extraction. A systematic review.

Authors:  J Ortega-Martínez; T Pérez-Pascual; S Mareque-Bueno; F Hernández-Alfaro; E Ferrés-Padró
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

7.  An alumina toughened zirconia composite for dental implant application: in vivo animal results.

Authors:  Gianmario Schierano; Federico Mussano; Maria Giulia Faga; Giulio Menicucci; Carlo Manzella; Cristian Sabione; Tullio Genova; Mitzy Mauthe von Degerfeld; Bruno Peirone; Adele Cassenti; Paola Cassoni; Stefano Carossa
Journal:  Biomed Res Int       Date:  2015-04-06       Impact factor: 3.411

8.  Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement supporting full-arch prostheses.

Authors:  Hilario Pellicer-Chover; David Peñarrocha-Oltra; Leticia Bagán; Antonio-J Fichy-Fernandez; Luigi Canullo; Miguel Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-05-01

Review 9.  Immediate loading implants: review of the critical aspects.

Authors:  L Tettamanti; C Andrisani; M Andreasi Bassi; R Vinci; J Silvestre-Rangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27

10.  A 5-year comparison of marginal bone level following immediate loading of single-tooth implants placed in healed alveolar ridges and extraction sockets in the maxilla.

Authors:  Antoine N Berberi; Joseph M Sabbagh; Moustafa N Aboushelib; Ziad F Noujeim; Ziad A Salameh
Journal:  Front Physiol       Date:  2014-01-31       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.