Literature DB >> 18807558

Surface characteristics of electrochemically oxidized implants and acid-etched implants: surface chemistry, morphology, pore configurations, oxide thickness, crystal structure, and roughness.

Young-Taeg Sul1, Eungsun Byon, Ann Wennerberg.   

Abstract

PURPOSE: This study was undertaken to investigate surface properties of surface-modified titanium implants in terms of surface chemistry, morphology, pore characteristics, oxide thickness, crystal structure, and roughness.
MATERIALS AND METHODS: An oxidized, custom-made Mg implant, an oxidized commercially available implant (TiUnite), and a dual acid-etched surface (Osseotite) were investigated. Surface characteristics were evaluated with various surface analytic techniques.
RESULTS: Surface chemistry showed similar fingerprints of titanium oxide and carbon contaminant in common for all implants but also revealed essential differences of the elements such as about 9 at% Mg for the Mg implant, about 11 at% P for the TiUnite implant and about 12 at% Na for the Osseotite implant. Surface morphology of the Mg and TiUnite implants demonstrated a duplex oxide structure, ie, an inner barrier layer without pores and an outer porous layer with numerous pores, whereas the Osseotite implant revealed a crystallographically etched appearance with pits. The diameter and depth of pores/pits was < or = 2 microm and < or = 1.5 microm in the Mg implant, < or = 4 microm and < or = 10 microm in the TiUnite implant, and < or = 2 microm and < or = 1 microm in the Osseotite implant, respectively. Oxide layer revealed homogeneous thickness, about 3.4 microm of all threads in the Mg implants. On the contrary, TiUnite showed heterogeneous oxide thickness, about 1 to 11 microm, which gradually increased with thread numbers. Crystal structure showed a mixture of anatase and rutile phase for the Mg implants. With respect to roughness, Sa showed 0.69 microm in the Mg implant, 1.35 microm in the TiUnite implant, and 0.72 microm in the Osseotite implant.
CONCLUSIONS: Well-defined surface characterization may provide a scientific basis for a better understanding of the effects of the implant surface on the biological response. The surface-engineered implants resulted in various surface characteristics, as a result of different manufacturing techniques.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18807558

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  12 in total

1.  Electrochemical etching of micro-pores in medical grade cobalt-chromium alloy as reservoirs for drug eluting stents.

Authors:  Kai Fuchsberger; Karoline Binder; Claus Burkhardt; Christian Freudigmann; Markus Herrmann; Martin Stelzle
Journal:  J Mater Sci Mater Med       Date:  2016-01-12       Impact factor: 3.896

2.  The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants.

Authors:  Ji-Hyun Kim; Yeek Herr; Jong-Hyuk Chung; Seung-Il Shin; Young-Hyuk Kwon
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

3.  Anodisation Increases Integration of Unloaded Titanium Implants in Sheep Mandible.

Authors:  Warwick J Duncan; Min-Ho Lee; Tae-Sung Bae; Sook-Jeong Lee; Jennifer Gay; Carolina Loch
Journal:  Biomed Res Int       Date:  2015-09-08       Impact factor: 3.411

Review 4.  Impact of Dental Implant Surface Modifications on Osseointegration.

Authors:  Ralf Smeets; Bernd Stadlinger; Frank Schwarz; Benedicta Beck-Broichsitter; Ole Jung; Clarissa Precht; Frank Kloss; Alexander Gröbe; Max Heiland; Tobias Ebker
Journal:  Biomed Res Int       Date:  2016-07-11       Impact factor: 3.411

5.  Immediate Function of Anodically Oxidized Surface Implants (TiUnite™) for Fixed Prosthetic Rehabilitation: Retrospective Study with 10 Years of Follow-Up.

Authors:  Paulo Maló; Miguel de Araújo Nobre; Yolande Gonçalves; Armando Lopes; Ana Ferro
Journal:  Biomed Res Int       Date:  2016-12-29       Impact factor: 3.411

6.  Long-Term Progressive Degradation of the Biological Capability of Titanium.

Authors:  Hajime Minamikawa; Wael Att; Takayuki Ikeda; Makoto Hirota; Takahiro Ogawa
Journal:  Materials (Basel)       Date:  2016-02-06       Impact factor: 3.623

7.  Decontamination of Titanium Surface Using Different Methods: An In Vitro Study.

Authors:  Sifan Yan; Min Li; Satoshi Komasa; Akinori Agariguchi; Yuanyuan Yang; Yuhao Zeng; Seiji Takao; Honghao Zhang; Yuichiro Tashiro; Tetsuji Kusumoto; Yasuyuki Kobayashi; Liji Chen; Kosuke Kashiwagi; Naoyuki Matsumoto; Joji Okazaki; Takayoshi Kawazoe
Journal:  Materials (Basel)       Date:  2020-05-15       Impact factor: 3.623

8.  Protein adsorption to surface chemistry and crystal structure modification of titanium surfaces.

Authors:  Ryo Jimbo; Mikael Ivarsson; Anita Koskela; Young-Taeg Sul; Carina B Johansson
Journal:  J Oral Maxillofac Res       Date:  2010-10-01

9.  Magnesium ion implantation on a micro/nanostructured titanium surface promotes its bioactivity and osteogenic differentiation function.

Authors:  Guifang Wang; Jinhua Li; Wenjie Zhang; Lianyi Xu; Hongya Pan; Jin Wen; Qianju Wu; Wenjun She; Ting Jiao; Xuanyong Liu; Xinquan Jiang
Journal:  Int J Nanomedicine       Date:  2014-05-21

10.  Characteristics and in vitro response of thin hydroxyapatite-titania films produced by plasma electrolytic oxidation of Ti alloys in electrolytes with particle additions.

Authors:  W K Yeung; I V Sukhorukova; D V Shtansky; E A Levashov; I Y Zhitnyak; N A Gloushankova; P V Kiryukhantsev-Korneev; M I Petrzhik; A Matthews; A Yerokhin
Journal:  RSC Adv       Date:  2016-02-01       Impact factor: 3.361

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.