Literature DB >> 18805599

Increase in coronary blood flow by intra-aortic balloon counterpulsation in a porcine model of myocardial reperfusion.

Michael J Bonios1, Charalampos N Pierrakos, Michael Argiriou, Argirios Dalianis, John V Terrovitis, Paraskevi Dolou, Stavros G Drakos, Dimitrios Koudoumas, Christos E Charitos, Maria I Anastasiou-Nana.   

Abstract

BACKGROUND: Studies of the IABP have reported variable effects on coronary blood flow (CBF). The purpose of the present study was to measure the changes in coronary blood flow induced by intra-aortic balloon pump (IABP) counterpulsation in normal and reperfused porcine myocardium.
METHODS: A 30-ml IABP was placed in the descending aorta of 6 open-chest pigs. Each pig underwent occlusion of the mid-left anterior descending (LAD) coronary artery for 1 h, followed by reperfusion for 2 h. The effects of IABP support on systolic aortic pressure (SAP) and aortic end-diastolic pressure were recorded. The mean CBF, distal to the LAD occlusion site was measured at baseline and during reperfusion, with and without IABP counterpulsation.
RESULTS: The IABP decreased SAP and aortic end-diastolic pressure in normal and reperfused myocardium, and maintained a peak aortic diastolic augmentation at the level of SAP. In normal myocardium, the IABP decreased mean CBF by 8.4+/-2.2% (p<0.001). At 2, 15, 30, 60, 90 and 120 min of reperfusion, the IABP increased mean CBF by 11.5+/-6.8%, 8.0+/-7.0%, 11.2+/-6.9%, 12.4+/-12.9%, 23.5+/-9.9% and 8.9+/-6.9%, of the corresponding value without the assistance of the IABP (all p<0.05).
CONCLUSIONS: In the normal heart, IABP counterpulsation decreased CBF, probably because of a decrease in myocardial oxygen demand from a decreased afterload. During reperfusion the IABP increased CBF, suggesting that it might effectively mitigate the no-reflow phenomenon. Copyright 2008 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2008        PMID: 18805599     DOI: 10.1016/j.ijcard.2008.08.015

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  4 in total

Review 1.  Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure.

Authors:  Christos D Kontogiannis; Konstantinos Malliaras; Chris J Kapelios; Jay W Mason; John N Nanas
Journal:  World J Transplant       Date:  2016-03-24

Review 2.  Cardiogenic shock in ACS. Part 2: Role of mechanical circulatory support.

Authors:  Stephen Westaby; Kyriakos Anastasiadis; George M Wieselthaler
Journal:  Nat Rev Cardiol       Date:  2012-01-10       Impact factor: 32.419

Review 3.  Mechanical Circulatory Support for Decompensated Heart Failure.

Authors:  Tarique Al Musa; Colin Dominic Chue; Hoong Sern Lim
Journal:  Curr Heart Fail Rep       Date:  2017-10

Review 4.  IABP: history-evolution-pathophysiology-indications: what we need to know.

Authors:  H Parissis; V Graham; S Lampridis; M Lau; G Hooks; P C Mhandu
Journal:  J Cardiothorac Surg       Date:  2016-08-04       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.