Literature DB >> 18805543

Proximal placement of limb electrodes: a potential solution for acquiring standard electrocardiogram waveforms from monitoring electrode positions.

Olle Pahlm1, Galen S Wagner.   

Abstract

There is currently a challenge to produce an electrocardiogram (ECG) recording of waveforms that are "standard" and also achieve the "noise immunity" required for continuous monitoring. The potential solutions that have been considered are to label each torso-recorded ECG as "nonstandard, torso-recorded," designate torso placement as "standard," or to reconstruct the "equivalent distally recorded ECG." The purpose of the present study was to validate an alternative "Lund system" of proximal limb electrode sites as a clinically feasible solution to this challenge. Data were collected from 75 patients referred for exercise testing at the Lund University Hospital. The Lund system produced Q wave dimensions and frontal plane QRS axis measurements that were in much better agreement with the standard ECG than those variables recorded with the Mason-Likar torso limb electrode method. Indeed, the Lund system replicated distal waveforms at a clinically acceptable level. Studies of larger patient cohorts including patients with various cardiac pathologies and studies of the noise immunity attained should be performed, and the acceptability by health care professionals should be determined.

Entities:  

Mesh:

Year:  2008        PMID: 18805543     DOI: 10.1016/j.jelectrocard.2008.06.019

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  3 in total

1.  An artificial neural network to safely reduce the number of ambulance ECGs transmitted for physician assessment in a system with prehospital detection of ST elevation myocardial infarction.

Authors:  Jakob L Forberg; Ardavan Khoshnood; Michael Green; Mattias Ohlsson; Jonas Björk; Stefan Jovinge; Lars Edenbrandt; Ulf Ekelund
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2012-02-01       Impact factor: 2.953

Review 2.  ECG monitoring leads and special leads.

Authors:  Johnson Francis
Journal:  Indian Pacing Electrophysiol J       Date:  2016-07-17

3.  Feasibility and Reliability of Smartwatch to Obtain Precordial Lead Electrocardiogram Recordings.

Authors:  Nora Sprenger; Alireza Sepehri Shamloo; Jonathan Schäfer; Sarah Burkhardt; Konstantinos Mouratis; Gerhard Hindricks; Andreas Bollmann; Arash Arya
Journal:  Sensors (Basel)       Date:  2022-02-05       Impact factor: 3.576

  3 in total