Mechanical modeling of self-expandable stent fabricated using braiding technology.

Ju Hyun Kim1, Tae Jin Kang, Woong-Ryeol Yu.   

Abstract

The mechanical behavior of a stent is one of the important factors involved in ensuring its opening within arterial conduits. This study aimed to develop a mechanical model for designing self-expandable stents fabricated using braiding technology. For this purpose, a finite element model was constructed by developing a preprocessing program for the three-dimensional geometrical modeling of the braiding structure inside stents, and validated for various stents with different braiding structures. The constituent wires (Nitinol) in the braided stents were assumed to be superelastic material and their mechanical behavior was incorporated into the finite element software through a user material subroutine (VUMAT in ABAQUS) employing a one-dimensional superelastic model. For the verification of the model, several braided stents were manufactured using an automated braiding machine and characterized focusing on their compressive behavior. It was observed that the braided stents showed a hysteresis between their loading and unloading behavior when a compressive load was applied to the braided tube. Through the finite element analysis, it was concluded that the current mechanical model can appropriately predict the mechanical behavior of braided stents including such hysteretic behavior, and that the hysteresis was caused by the slippage between the constituent wires and their superelastic property.

Entities:  

Mesh:

Year:  2008        PMID: 18804764     DOI: 10.1016/j.jbiomech.2008.08.005

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  11 in total

1.  An in vitro study of silk stent morphology.

Authors:  Thaweesak Aurboonyawat; Raphaël Blanc; Paul Schmidt; Michel Piotin; Laurent Spelle; Amir Nakib; Jacques Moret
Journal:  Neuroradiology       Date:  2010-10-28       Impact factor: 2.804

2.  Comparison of Pipeline Embolization Device Sizing Based on Conventional 2D Measurements and Virtual Simulation Using the Sim&Size Software: An Agreement Study.

Authors:  J M Ospel; G Gascou; V Costalat; L Piergallini; K A Blackham; D W Zumofen
Journal:  AJNR Am J Neuroradiol       Date:  2019-02-07       Impact factor: 3.825

3.  Virtual-versus-Real Implantation of Flow Diverters: Clinical Potential and Influence of Vascular Geometry.

Authors:  P Bouillot; O Brina; H Yilmaz; M Farhat; G Erceg; K-O Lovblad; M I Vargas; Z Kulcsar; V M Pereira
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-30       Impact factor: 3.825

4.  High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: in vitro and in silico.

Authors:  Ding Ma; Travis M Dumont; Hiroyuki Kosukegawa; Makoto Ohta; Xinjian Yang; Adnan H Siddiqui; Hui Meng
Journal:  Ann Biomed Eng       Date:  2013-04-20       Impact factor: 3.934

5.  Intraductal Tissue Sampling Device Designed for the Biliary Tract.

Authors:  Malay S Patel; Matthew D Carson; Eric J Seibel; Lucas R Meza
Journal:  IEEE J Transl Eng Health Med       Date:  2021-02-04       Impact factor: 3.316

6.  Hemodynamic Changes Caused by Flow Diverters in Rabbit Aneurysm Models: Comparison of Virtual and Realistic FD Deployments Based on Micro-CT Reconstruction.

Authors:  Jinyu Xu; Benqiang Deng; Yibin Fang; Ying Yu; Jiyong Cheng; Shengzhang Wang; Kuizhong Wang; Jian-Min Liu; Qinghai Huang
Journal:  PLoS One       Date:  2013-06-18       Impact factor: 3.240

Review 7.  Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries.

Authors:  Charanpreet Singh; Cynthia S Wong; Xungai Wang
Journal:  J Funct Biomater       Date:  2015-06-30

8.  Selection of helical braided flow diverter stents based on hemodynamic performance and mechanical properties.

Authors:  Takashi Suzuki; Hiroyuki Takao; Soichiro Fujimura; Chihebeddine Dahmani; Toshihiro Ishibashi; Hiroya Mamori; Naoya Fukushima; Makoto Yamamoto; Yuichi Murayama
Journal:  J Neurointerv Surg       Date:  2016-09-19       Impact factor: 5.836

9.  Mechanical characterizations of braided composite stents made of helical polyethylene terephthalate strips and NiTi wires.

Authors:  Qingli Zheng; Pengfei Dong; Zhiqiang Li; Xinwei Han; Changchun Zhou; Meiwen An; Linxia Gu
Journal:  Nanotechnol Rev       Date:  2019-11-06       Impact factor: 6.739

10.  Design of barrier coatings on kink-resistant peripheral nerve conduits.

Authors:  Basak Acan Clements; Jared Bushman; N Sanjeeva Murthy; Mindy Ezra; Christopher M Pastore; Joachim Kohn
Journal:  J Tissue Eng       Date:  2016-02-05       Impact factor: 7.813