Literature DB >> 18803333

Quantification of small molecules in plasma with direct analysis in real time tandem mass spectrometry, without sample preparation and liquid chromatographic separation.

Yeping Zhao1, Michelle Lam, Danlin Wu, Rowena Mak.   

Abstract

Recently, a new ion source, Direct Analysis in Real Time (DART), has been introduced which allows direct biological sample introduction into a mass spectrometry (MS) system. The elimination of conventionally required sample preparation and separation by high-performance liquid chromatography (HPLC) prior to MS analysis represents a remarkable opportunity to reduce assay turn-around time, environmental impact and capital/manpower investment. This new technology initially was used in various qualitative applications to directly detect chemicals on solid surfaces, in liquids and gases. In this study, a DART source operating under ambient pressure with ground potential was installed onto a Sciex 4000 tandem mass spectrometer and employed in the sample analysis of plasma based on direct introduction into the DART-MS/MS system. Reasonable precision and accuracy (%CV and %Error, both <10%) were achieved of a significant number of compounds tested in biological fluids. In addition, the limit of detection for 80% of the tested compounds reached 5 ng/mL or lower which is sufficient for pharmaceutical drug discovery support. Finally, experimental conditions that significantly impacted assay performance were investigated with respect to optimization and limitation. Because of its simplicity, fast data acquisition (3-5 s) and low cost, DART has the potential to significantly impact quantitative pharmaceutical analysis in biological matrices.

Mesh:

Substances:

Year:  2008        PMID: 18803333     DOI: 10.1002/rcm.3726

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  10 in total

1.  Multimodal Vacuum-Assisted Plasma Ion (VaPI) Source with Transmission Mode and Laser Ablation Sampling Capabilities.

Authors:  Joel D Keelor; Paul B Farnsworth; Arthur L Weber; Heather Abbott-Lyon; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-16       Impact factor: 3.109

2.  Determination of Dicyandiamide in Powdered Milk Using Direct Analysis in Real Time Quadrupole Time-of-Flight Tandem Mass Spectrometry.

Authors:  Liya Zhang; Wei Yong; Jiahui Liu; Sai Wang; Qilong Chen; Tianyang Guo; Jichuan Zhang; Tianwei Tan; Haijia Su; Yiyang Dong
Journal:  J Am Soc Mass Spectrom       Date:  2015-05-01       Impact factor: 3.109

3.  Optimization of a direct analysis in real time/time-of-flight mass spectrometry method for rapid serum metabolomic fingerprinting.

Authors:  Manshui Zhou; John F McDonald; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2009-09-17       Impact factor: 3.109

Review 4.  Direct sampling mass spectrometry for clinical analysis.

Authors:  Fan Pu; Spencer Chiang; Wenpeng Zhang; Zheng Ouyang
Journal:  Analyst       Date:  2019-02-11       Impact factor: 4.616

5.  Analysis of silicones released from household items and baby articles by direct analysis in real time-mass spectrometry.

Authors:  Jürgen H Gross
Journal:  J Am Soc Mass Spectrom       Date:  2014-12-16       Impact factor: 3.109

6.  What Is the Opposite of Pandora's Box? Direct Analysis, Ambient Ionization, and a New Generation of Atmospheric Pressure Ion Sources.

Authors:  Robert B Cody
Journal:  Mass Spectrom (Tokyo)       Date:  2013-04-15

Review 7.  Trends in the application of high-resolution mass spectrometry for human biomonitoring: An analytical primer to studying the environmental chemical space of the human exposome.

Authors:  Syam S Andra; Christine Austin; Dhavalkumar Patel; Georgia Dolios; Mahmoud Awawda; Manish Arora
Journal:  Environ Int       Date:  2017-01-04       Impact factor: 9.621

8.  Advances in structure elucidation of small molecules using mass spectrometry.

Authors:  Tobias Kind; Oliver Fiehn
Journal:  Bioanal Rev       Date:  2010-08-21

9.  Simultaneous determination of 3-chlorotyrosine and 3-nitrotyrosine in human plasma by direct analysis in real time-tandem mass spectrometry.

Authors:  Yuqiao Song; Jie Liao; Cheng Zha; Bin Wang; Charles C Liu
Journal:  Acta Pharm Sin B       Date:  2015-08-29       Impact factor: 11.413

10.  Comment on: "Analysis of Silicones Released from Household Items and Baby Articles by Direct Analysis in Real Time-Mass Spectrometry" by Jürgen H. Gross. J. Am. Soc. Mass Spectrom. 26, 511-521 (2015).

Authors:  Karluss Thomas
Journal:  J Am Soc Mass Spectrom       Date:  2016-08       Impact factor: 3.109

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.