Abstract

In this study we reviewed the treatment outcomes for 20 consecutive patients who underwent anterior 1-level cervical corpectomy and reconstruction using a titanium mesh cage and semi-constrained plating after an average follow-up of 14.8 months. Two groups, each of 10 patients, underwent surgery with 10-mm and 13-mm diameter cages, respectively. Bony fusion and the radiological outcome were evaluated using follow-up radiography and sagittal reconstructed CT scans. The radiographs revealed bony consolidation in 95% of the 20 patients during follow-up. Five cases of construct failure occurred after surgery:1 failure (10%) was encountered in the 10-mm cage group and 4 (40%) occurred in the 13-mm cage group (P=0.085). The failures were mainly the result of cage settling and screw-plate failure. Although the clinical outcomes and fusion rates for anterior cervical stabilization using a semi-constrained plate and titanium cage were favorable, further biomechanical evaluations and a prospective randomized study will be necessary to fully understand this dependence of implant failure on cage size.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18801657     DOI: 10.1016/j.jocn.2007.09.019

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  5 in total

1.  Evaluation of a new type of titanium mesh cage versus the traditional titanium mesh cage for single-level, anterior cervical corpectomy and fusion.

Authors:  Yu Fengbin; Miao Jinhao; Liao Xinyuan; Wang Xinwei; Chen Yu; Chen Deyu
Journal:  Eur Spine J       Date:  2013-09-03       Impact factor: 3.134

2.  Evaluation of anterior cervical reconstruction with titanium mesh cages versus nano-hydroxyapatite/polyamide66 cages after 1- or 2-level corpectomy for multilevel cervical spondylotic myelopathy: a retrospective study of 117 patients.

Authors:  Yuan Zhang; Zhengxue Quan; Zenghui Zhao; Xiaoji Luo; Ke Tang; Jie Li; Xu Zhou; Dianming Jiang
Journal:  PLoS One       Date:  2014-05-02       Impact factor: 3.240

3.  Preventing Construct Subsidence Following Cervical Corpectomy: The Bump-stop Technique.

Authors:  Kenneth Aaron Shaw; Matthew Griffith; Edward T Mottern; David M Gloystein; John G Devine
Journal:  Asian Spine J       Date:  2018-02-07

Review 4.  Anterior Cervical Corpectomy and Fusion and Anterior Cervical Discectomy and Fusion Using Titanium Mesh Cages for Treatment of Degenerative Cervical Pathologies: A Literature Review.

Authors:  Zhijing Wen; Teng Lu; Yibin Wang; Hui Liang; Zhengchao Gao; Xijing He
Journal:  Med Sci Monit       Date:  2018-09-12

5.  A novel anatomic titanium mesh cage for reducing the subsidence rate after anterior cervical corpectomy: a finite element study.

Authors:  Yuhang Wang; Yi Zhan; Huiming Yang; Hua Guo; Haiping Zhang; Qinpeng Zhao; Dingjun Hao; Biao Wang
Journal:  Sci Rep       Date:  2021-07-28       Impact factor: 4.379