| Literature DB >> 18799325 |
Thomas Youm1, Neal S ElAttrache, James E Tibone, Michelle H McGarry, Thay Q Lee.
Abstract
The long head of the biceps has been described as a stabilizing force in the setting of glenohumeral instability. However, data are lacking on the effect of loading the long head of the biceps on glenohumeral kinematics. Six cadaveric shoulders were tested for glenohumeral rotational range of motion and translation using a custom shoulder testing system and the Microscribe 3DLX (Immersion, San Jose, CA). The path of glenohumeral articulation (PGA) was measured by calculating the humeral head center with respect to the glenoid articular surface at maximal internal rotation, 30 degrees, 60 degrees, 90 degrees, and maximal external rotation. Significant decreases in glenohumeral rotational range of motion and translation were found with 22-N biceps loading vs the unloaded group. With respect to the PGA, the humeral rotation center was shifted posterior with biceps loading at maximal internal rotation, 30 degrees, and 60 degrees of external rotation. Loading the long head of the biceps significantly affects glenohumeral rotational range of motion, translations, and kinematics.Entities:
Mesh:
Year: 2008 PMID: 18799325 DOI: 10.1016/j.jse.2008.06.003
Source DB: PubMed Journal: J Shoulder Elbow Surg ISSN: 1058-2746 Impact factor: 3.019