Literature DB >> 18799302

A novel reagentless amperometric immunosensor based on gold nanoparticles/TMB/Nafion-modified electrode.

Ying Wu1, Junwei Zheng, Zheng Li, Yanrong Zhao, Yu Zhang.   

Abstract

A novel reagentless immunosensor was fabricated by immobilization of redox mediator 3,3',5,5'-tetramethylbenzidine (TMB) on the Nafion (Nf) film modified glassy carbon electrode. Gold nanoparticles were assembled onto the TMB/Nafion film modified electrode to provide active sites for the immobilization of antibody molecules. The antibody (anti-MIgG), in the present study, was fixed on the electrode for the rapid detection of antigen molecules (MIgG as a model analyte). The results showed that the immunosensor based on the immobilized TMB redox mediator exhibited good electrochemical response. A good linear relationship between peak current and the concentration of the MIgG was obtained in the concentration range from 4 to 120ng/mL. The detection limit was estimated to be 1ng/ml. Under the optimized conditions, the immunosensor exhibits good sensitivity, reproducibility and stability.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18799302     DOI: 10.1016/j.bios.2008.07.075

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Gold nanoparticles in chemical and biological sensing.

Authors:  Krishnendu Saha; Sarit S Agasti; Chaekyu Kim; Xiaoning Li; Vincent M Rotello
Journal:  Chem Rev       Date:  2012-02-02       Impact factor: 60.622

Review 2.  Prospects of nanotechnology in clinical immunodiagnostics.

Authors:  Anees A Ansari; Mansour Alhoshan; Mohamad S Alsalhi; Abdullah S Aldwayyan
Journal:  Sensors (Basel)       Date:  2010-07-07       Impact factor: 3.576

3.  An amperometric immunosensor based on a polyelectrolyte/gold magnetic nanoparticle supramolecular assembly--modified electrode for the determination of HIV p24 in serum.

Authors:  Ning Gan; Jianguo Hou; Futao Hu; Lei Zheng; Minjun Ni; Yuting Cao
Journal:  Molecules       Date:  2010-07-23       Impact factor: 4.411

4.  Determination of Cr(VI) based on the peroxidase mimetic catalytic activity of citrate-capped gold nanoparticles.

Authors:  Yingying Qi; Jinxin Ma; Fu-Rong Xiu; Xiang Gao
Journal:  Mikrochim Acta       Date:  2021-07-26       Impact factor: 5.833

Review 5.  Integration of biosensors and drug delivery technologies for early detection and chronic management of illness.

Authors:  Mpho Ngoepe; Yahya E Choonara; Charu Tyagi; Lomas Kumar Tomar; Lisa C du Toit; Pradeep Kumar; Valence M K Ndesendo; Viness Pillay
Journal:  Sensors (Basel)       Date:  2013-06-14       Impact factor: 3.576

6.  All-printed highly sensitive 2D MoS2 based multi-reagent immunosensor for smartphone based point-of-care diagnosis.

Authors:  Memoon Sajid; Ahmed Osman; Ghayas Uddin Siddiqui; Hyun Bum Kim; Soo Wan Kim; Jeong Bum Ko; Yoon Kyu Lim; Kyung Hyun Choi
Journal:  Sci Rep       Date:  2017-07-19       Impact factor: 4.379

  6 in total