Abstract

BACKGROUND: The histamine releasing test which detects histamine released from basophils in vitro is safe, sensitive and widely used for clinical examination in the field of allergy. However, basophils of certain individuals do not release histamine, because of dysfunctions in their intracellular signal transduction (non-responder). To overcome potential shortcomings of the histamine releasing test, we applied surface plasmon resonance (SPR) to detect the activation of basophils.
METHODS: Basophils of patients with allergy, and those of non-allergic volunteers were isolated from peripheral blood. A batch of basophils obtained from a healthy volunteer was treated with lactic acid and IgE of a patient with atopic dermatitis in order to replace their endogenous IgE. They were fixed on the sensor chip of the SPR apparatus, pretreated with or without various inhibitors for intracellular signal transduction, and exposed to the antigens or anti-IgE antibody.
RESULTS: When basophils were sensitized with antigen specific IgE, they immediately caused the increase of resonance angle (AR) in response to either anti-IgE antibody or corresponding antigens, even when they did not release histamine. Moreover, the dose dependent reactions of basophils were reflected by the increase of AR as well as the release of histamine. The increase of AR in response to anti-IgE antibody was reduced by pre-treatment of basophils with inhibitors for intracellular signal transduction, but not more than the level for histamine release.
CONCLUSIONS: SPR biosensors may be superior to the histamine release test for studying functions of human basophils including those not releasing histamine.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18797180     DOI: 10.2332/allergolint.O-07-506

Source DB:  PubMed          Journal:  Allergol Int        ISSN: 1323-8930            Impact factor:   5.836


  8 in total

Review 1.  Microfluidic methods for precision diagnostics in food allergy.

Authors:  Nicolas Castaño; Seth C Cordts; Kari C Nadeau; Mindy Tsai; Stephen J Galli; Sindy K Y Tang
Journal:  Biomicrofluidics       Date:  2020-04-03       Impact factor: 2.800

2.  Inhibition of CD203c membrane up-regulation in human basophils by high dilutions of histamine: a controlled replication study.

Authors:  Salvatore Chirumbolo; Maurizio Brizzi; Riccardo Ortolani; Antonio Vella; Paolo Bellavite
Journal:  Inflamm Res       Date:  2009-05-06       Impact factor: 4.575

3.  Carboplatin-induced severe hypersensitivity reaction: role of IgE-dependent basophil activation and FcεRI.

Authors:  Takuya Iwamoto; Hiroyuki Hirai; Nozomi Yamaguchi; Natsuki Kobayashi; Hiroko Sugimoto; Tsutomu Tabata; Masahiro Okuda
Journal:  Cancer Sci       Date:  2014-11-05       Impact factor: 6.716

Review 4.  Surface plasmon resonance for cell-based clinical diagnosis.

Authors:  Yuhki Yanase; Takaaki Hiragun; Kaori Ishii; Tomoko Kawaguchi; Tetsuji Yanase; Mikio Kawai; Kenji Sakamoto; Michihiro Hide
Journal:  Sensors (Basel)       Date:  2014-03-11       Impact factor: 3.576

5.  Impedance-Based Living Cell Analysis for Clinical Diagnosis of Type I Allergy.

Authors:  Reiko Irifuku; Yuhki Yanase; Tomoko Kawaguchi; Kaori Ishii; Shunsuke Takahagi; Michihiro Hide
Journal:  Sensors (Basel)       Date:  2017-10-31       Impact factor: 3.576

6.  Discovery of Orphan Olfactory Receptor 6M1 as a New Anticancer Target in MCF-7 Cells by a Combination of Surface Plasmon Resonance-Based and Cell-Based Systems.

Authors:  Yae Rim Choi; Jaewon Shim; Jae-Ho Park; Young-Suk Kim; Min Jung Kim
Journal:  Sensors (Basel)       Date:  2021-05-16       Impact factor: 3.576

7.  A novel approach to predict cetuximab-induced hypersensitivity reaction: detection of drug-specific IgE on basophils.

Authors:  Takuya Iwamoto; Akiharu Okamoto; Hajime Ishinaga; Kasumi Shimizu; Alberto A Gayle; Naoya Arai; Kazuhiko Takeuchi; Masahiro Okuda
Journal:  Cancer Med       Date:  2016-02-16       Impact factor: 4.452

8.  Development of SPR Imaging-Impedance Sensor for Multi-Parametric Living Cell Analysis.

Authors:  Yuhki Yanase; Kyohei Yoshizaki; Kaiken Kimura; Tomoko Kawaguchi; Michihiro Hide; Shigeyasu Uno
Journal:  Sensors (Basel)       Date:  2019-05-03       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.