Literature DB >> 18796845

Hand-held Dynamometer Measurements: Tester Strength Makes a Difference.

J B Wikholm, R W Bohannon.   

Abstract

Three examiners with measurably different strengths and three muscle groups with distinctly different maximum force productions were used to investigate the effect of tester strength on the magnitude and reliability of hand-held dynamometer (HHD) force measurements. Each examiner measured the shoulder external rotator, elbow flexor, and knee extensor muscles of 27 healthy adults twice during two sessions (one week apart). Intrarater/intrasession, intrarater/intersession, and interrater/intrasession reliability coefficients (ICCs) were calculated. Interrater ICCs decreased in magnitude (.932 to .226) as the tested muscle groups increased in force production. Intrarater/intersession ICCs indicated a similar trend. High intrarater/intrasession and interrater/intrasession ICCs calculated from shoulder external rotator measurements indicated that HHD testing for muscle groups generating a mean maximum force of about 120 N may be reliable for clinicians with strengths equal to or exceeding those of the weakest tester in this study. Above 120 N, tester strength appeared to be a major determinant of the magnitude and reliability of the forces measured with a HHD. Further investigation into the relationship between tester strength and the intrarater and interrater reliability of HHD measurements is warranted. J Orthop Sports Phys Ther 1991;13(4):191-198.

Entities:  

Year:  1991        PMID: 18796845     DOI: 10.2519/jospt.1991.13.4.191

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  55 in total

Review 1.  Effect of vitamin D supplementation on muscle strength: a systematic review and meta-analysis.

Authors:  K A Stockton; K Mengersen; J D Paratz; D Kandiah; K L Bennell
Journal:  Osteoporos Int       Date:  2010-10-06       Impact factor: 4.507

2.  A narrative review of manual muscle testing and implications for muscle testing research.

Authors:  Katharine M Conable; Anthony L Rosner
Journal:  J Chiropr Med       Date:  2011-08-09

3.  Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable.

Authors:  Kristian Thorborg; Thomas Bandholm; Per Hölmich
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-07       Impact factor: 4.342

4.  Can a clinical test of hamstring strength identify football players at risk of hamstring strain?

Authors:  Anthony G Schache; Kay M Crossley; Ian G Macindoe; Brendan B Fahrner; Marcus G Pandy
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-10       Impact factor: 4.342

5.  Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer.

Authors:  Frank Tudini; Bradley Myers; Richard Bohannon
Journal:  J Man Manip Ther       Date:  2019-03-18

6.  The relationship between corticospinal tract integrity and lower-extremity strength is attenuated when controlling for age and sex in multiple sclerosis.

Authors:  Jessica F Baird; Elizabeth A Hubbard; Bradley P Sutton; Robert W Motl
Journal:  Brain Res       Date:  2018-09-10       Impact factor: 3.252

7.  RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER.

Authors:  Martin Alfuth; Magali Murielle Hahm
Journal:  Int J Sports Phys Ther       Date:  2016-02

8.  Computer-assisted hand-held dynamometer: low-cost instrument for muscle function assessment in rehabilitation medicine.

Authors:  J Harlaar; M E Roebroeck; G J Lankhorst
Journal:  Med Biol Eng Comput       Date:  1996-09       Impact factor: 2.602

9.  The impact of sagittal plane hip position on isometric force of hip external rotator and internal rotator muscles in healthy young adults.

Authors:  Lisa T Hoglund; Anson L K Wong; Cory Rickards
Journal:  Int J Sports Phys Ther       Date:  2014-02

10.  Evaluating the reliability of a novel neck-strength assessment protocol for healthy adults using self-generated resistance with a hand-held dynamometer.

Authors:  Theo Versteegh; Danielle Beaudet; Marla Greenbaum; Leah Hellyer; Amanda Tritton; Dave Walton
Journal:  Physiother Can       Date:  2015       Impact factor: 1.037

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.