Literature DB >> 18796577

Intraoperative acoustic evaluation of living human cartilage of the elbow and knee during mosaicplasty for osteochondritis dissecans of the elbow: an in vivo study.

Kohei Nishitani1, Yasuaki Nakagawa, Tadashi Gotoh, Masahiko Kobayashi, Takashi Nakamura.   

Abstract

BACKGROUND: Autologous osteochondral mosaicplasty for osteochondritis dissecans of the capitellum is being used increasingly in adolescent patients. Little research has been published on the material properties of living human cartilage of the elbow and knee. HYPOTHESIS: The cartilage of the osteochondritis dissecans lesion is detected as degenerated by ultrasound. The material properties of the cartilage of the intact part of the elbow are not different from those of the intact knee except in thickness. STUDY
DESIGN: Descriptive laboratory study.
METHODS: The authors studied 10 young male athletes with osteochondritis dissecans of the capitellum who underwent mosaicplasty. An acoustic probe was used for measurement, and the wavelet transform method was used. Three parameters were used: signal intensity (index of cartilage stiffness), signal duration (index of roughness), and signal interval (index of thickness).
RESULTS: The cartilage of the osteochondritis dissecans lesion had lower signal intensity than did the intact part of the capitellum. The cartilage of the radial head opposite the capitellum had significantly lower signal intensity and higher signal duration than did other sites. The signal intensity of the radial head was significantly higher in early-stage patients than in late-stage patients, although the macroscopic view was almost all intact. The signal intensity of the plug was decreased significantly after grafting.
CONCLUSION: The osteochondritis dissecans lesion had lower signal intensity than did the intact part of the capitellum. Although the macroscopic view looked intact, the radial head cartilage was degenerated as measured acoustically. CLINICAL RELEVANCE: Not only the cartilage of the capitellum but the cartilage of the radial head are acoustically degenerated in osteochondritis dissecans patients. Plugs might be damaged in the transplanting procedure, and further follow-up is necessary.

Entities:  

Mesh:

Year:  2008        PMID: 18796577     DOI: 10.1177/0363546508322898

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  5 in total

1.  Ultrasound has the potential to detect degeneration of articular cartilage clinically, even if the information is obtained from an indirect measurement of intrinsic physical characteristics.

Authors:  Hiroshi Kuroki; Yasuaki Nakagawa; Koji Mori; Masahiko Kobayashi; Ko Yasura; Yukihiro Okamoto; Takashi Suzuki; Kohei Nishitani; Takashi Nakamura
Journal:  Arthritis Res Ther       Date:  2009       Impact factor: 5.156

2.  In Vivo Evaluation of the Potential of High-Frequency Ultrasound for Arthroscopic Examination of the Shoulder Joint.

Authors:  Jani Puhakka; Isaac O Afara; Teemu Paatela; Markus J Sormaala; Matti A Timonen; Tuomas Virén; Jukka S Jurvelin; Juha Töyräs; Ilkka Kiviranta
Journal:  Cartilage       Date:  2015-11-26       Impact factor: 4.634

3.  Arthroscopic Ultrasound Assessment of Articular Cartilage in the Human Knee Joint: A Potential Diagnostic Method.

Authors:  Erna Kaleva; Tuomas Virén; Simo Saarakkala; Janne Sahlman; Joonas Sirola; Jani Puhakka; Teemu Paatela; Heikki Kröger; Ilkka Kiviranta; Jukka S Jurvelin; Juha Töyräs
Journal:  Cartilage       Date:  2011-07       Impact factor: 4.634

4.  Mechanical effects of surgical procedures on osteochondral grafts elucidated by osmotic loading and real-time ultrasound.

Authors:  Koji Hattori; Kota Uematsu; Tomohiro Matsumoto; Hajime Ohgushi
Journal:  Arthritis Res Ther       Date:  2009-09-02       Impact factor: 5.156

5.  Ultrasound can detect macroscopically undetectable changes in osteoarthritis reflecting the superficial histological and biochemical degeneration: ex vivo study of rabbit and human cartilage.

Authors:  Kohei Nishitani; Masahiko Kobayashi; Hiroshi Kuroki; Koji Mori; Takaaki Shirai; Tsuyoshi Satake; Shinnichiro Nakamura; Ryuzo Arai; Yasuaki Nakagawa; Takashi Nakamura; Shuichi Matsuda
Journal:  PLoS One       Date:  2014-02-21       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.