Determination of shear strength of periosteum attached to bone with BioGlue Surgical Adhesive.

Douglas M Sidle1, Corey S Maas.   

Abstract

OBJECTIVE: To determine the shear strength of BioGlue Surgical Adhesive (Cryolife Inc, Kennesaw, Georgia) for use in periosteal fixation in endoscopic browplasty.
METHODS: In a controlled design, the shear strength of periosteal attachment to native bone and that of dissected periosteum affixed to bone with BioGlue surgical adhesive was physiologically determined. Twenty-one periosteum and bone samples were harvested from 3 human cadavers. These samples were tested for maximum shear strength using an Instron Model 5500 universal materials testing machine. Native samples consisted of periosteum still attached to the bone surface, while BioGlue samples consisted of dissected periosteum reattached to the bone surface using BioGlue surgical adhesive. The maximum shear strength attained for each sample was recorded and used to determine if native samples differed from those using BioGlue surgical adhesive.
RESULTS: The mean (SD) maximum shear strength values obtained during testing were 57.8 (31.7) kPa and 45.9 (27.4) kPa (589.4 [323.3] gram force [gf]/cm(2) and 468.0 [279.4] gf/cm(2)) for native (n=8) and BioGlue (n=9) samples, respectively. There was no statistical difference between the native and BioGlue samples (P> .05) using analysis of variance.
CONCLUSION: This study demonstrates that the adhesive properties of BioGlue are similar to the strength of attachment of native periosteum to bone and supports the use of BioGlue as an alternative method of fixation for use in endoscopic brow-lifting.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18794409     DOI: 10.1001/archfaci.10.5.316

Source DB:  PubMed          Journal:  Arch Facial Plast Surg        ISSN: 1521-2491


  4 in total

1.  A highly elastic and adhesive gelatin tissue sealant for gastrointestinal surgery and colon anastomosis.

Authors:  Tony Vuocolo; Roger Haddad; Glenn A Edwards; Russell E Lyons; Nancy E Liyou; Jerome A Werkmeister; John A M Ramshaw; Christopher M Elvin
Journal:  J Gastrointest Surg       Date:  2011-11-12       Impact factor: 3.452

2.  Investigation of surgical adhesives for vocal fold wound closure.

Authors:  Lei Xi Chen; Maxence Coulombe; Francois Barthelat; Almoaidbellah Rammal; Luc Mongeau; Karen Kost
Journal:  Laryngoscope       Date:  2019-03-18       Impact factor: 3.325

3.  A comparison of a bovine albumin/glutaraldehyde glue versus fibrin sealant for hernia mesh fixation in experimental onlay and IPOM repair in rats.

Authors:  S Gruber-Blum; A H Petter-Puchner; K Mika; J Brand; H Redl; W Ohlinger; T Benesch; R H Fortelny
Journal:  Surg Endosc       Date:  2010-05-29       Impact factor: 4.584

4.  A biomechanical test model for evaluating osseous and osteochondral tissue adhesives.

Authors:  Philip Procter; Michael Pujari-Palmer; Gry Hulsart-Billström; David Wenner; Gerard Insley; Sune Larsson; Håkan Engqvist
Journal:  BMC Biomed Eng       Date:  2019-05-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.