Literature DB >> 18794264

Real-time iterative monitoring of radiofrequency ablation tumor therapy with 15O-water PET imaging.

Ande Bao1, Beth Goins, Gerald D Dodd, Anuradha Soundararajan, Cristina Santoyo, Randal A Otto, Michael D Davis, William T Phillips.   

Abstract

UNLABELLED: A method that provides real-time image-based monitoring of solid tumor therapy to ensure complete tumor eradication during image-guided interventional therapy would be a valuable tool. The short, 2-min half-life of (15)O makes it possible to perform repeated PET imaging at 20-min intervals at multiple time points before and after image-guided therapy. In this study, (15)O-water PET was evaluated as a tool to provide real-time feedback and iterative image guidance to rapidly monitor the intratumoral coverage of radiofrequency (RF) ablation therapy.
METHODS: Tumor RF ablation therapy was performed on head and neck squamous cell carcinoma (SCC) xenograft tumors (length, approximately 23 mm) in 6 nude rats. The tumor in each animal was ablated with RF (1-cm active size ablation catheter, 70 degrees C for 5 min) twice in 2 separate tumor regions with a 20-min separation. The (15)O-water PET images were acquired before RF ablation and after the first RF and second RF ablations using a small-animal PET scanner. In each PET session, approximately 100 MBq of (15)O-water in 1.0 mL of saline were injected intravenously into each animal. List-mode PET images were acquired for 7 min starting 20 s before injection. PET images were reconstructed by 2-dimensional ordered-subset expectation maximization into single-frame images and dynamic images at 10 s/frame. PET images were displayed and analyzed with software.
RESULTS: Pre-RF ablation images demonstrate that (15)O-water accumulates in tumors with (15)O activity reaching peak levels immediately after administration. After RF ablation, the ablated region had almost zero activity, whereas the unablated tumor tissue continued to have a high (15)O-water accumulation. Using image feedback, the RF probe was repositioned to a tumor region with residual (15)O-water uptake and then ablated. The second RF ablation in this new region of the tumor resulted in additional ablation of the solid tumor, with a corresponding decrease in activity on the (15)O-water PET image.
CONCLUSION: (15)O-water PET clearly demonstrated the ablated tumor region, whereas the unablated tumor continued to show high (15)O-water accumulation. (15)O-water imaging shows promise as a tool for on-site, real-time monitoring of image-guided interventional cancer therapy.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18794264     DOI: 10.2967/jnumed.108.052886

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

Review 1.  Interventional Molecular Imaging.

Authors:  Stephen B Solomon; Francois Cornelis
Journal:  J Nucl Med       Date:  2016-02-11       Impact factor: 10.057

Review 2.  The Role of PET Imaging Before, During, and After Percutaneous Hepatic and Pulmonary Tumor Ablation.

Authors:  Eric D McLoney; Ari J Isaacson; Patrick Keating
Journal:  Semin Intervent Radiol       Date:  2014-06       Impact factor: 1.513

3.  Laser thermal therapy monitoring using complex differential variance in optical coherence tomography.

Authors:  William C Y Lo; Néstor Uribe-Patarroyo; Ahhyun S Nam; Martin Villiger; Benjamin J Vakoc; Brett E Bouma
Journal:  J Biophotonics       Date:  2016-09-14       Impact factor: 3.207

4.  A Review of Imaging Methods to Assess Ultrasound-Mediated Ablation.

Authors:  Brett Z Fite; James Wang; Pejman Ghanouni; Katherine W Ferrara
Journal:  BME Front       Date:  2022-05-02
  4 in total