Literature DB >> 18793928

Evaluation of a rotary instrumentation method for C-shaped canals with micro-computed tomography.

Lisa H M Cheung1, Gary S P Cheung.   

Abstract

This study aimed to evaluate the safety and efficacy of a method of using nickel-titanium rotary instruments for preparing the C-shaped root canal system. Forty-three human mandibular second molars with a C-shaped canal configuration were prepared with a crown-down approach to an apical dimension of size 30 by using a combination of ProFile and HERO instruments. Micro-computed tomography was used to examine the canal diameter and the remaining thickness of the dentin wall along the root canal. Results showed that only isolated regions in cross section of the C-shaped canal were physically prepared by the rotary instruments. The furcal wall (concave aspect of the "C" in cross section) of all clinically identifiable canals had a similar thickness at a distance 1-7 mm from the apical constriction both before and after instrumentation. More dentin was removed from the outer (convex aspect of the "C") than the furcal aspect at the apical region, but the converse was true more coronally. All prepared canals showed a taper that matched that of the last instrument used. It was concluded that cleaning of the C-shaped canal system is incomplete with the use of rotary instruments and should be assisted by ultrasonic irrigation. Although rotary instruments seemed to be safe in such canals, further enlargement to an apical dimension greater than size 30 (0.06 taper) is not recommended.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18793928     DOI: 10.1016/j.joen.2008.07.015

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  Root and Root Canal Configuration Characterization Using Microcomputed Tomography: A Systematic Review.

Authors:  Mohmed Isaqali Karobari; Sohaib Arshad; Tahir Yusuf Noorani; Naveed Ahmed; Syed Nahid Basheer; Syed Wali Peeran; Anand Marya; Charu Mohan Marya; Pietro Messina; Giuseppe Alessandro Scardina
Journal:  J Clin Med       Date:  2022-04-20       Impact factor: 4.964

Review 2.  The Influence of New Bioactive Materials on Pulp-Dentin Complex Regeneration in the Assessment of Cone Bone Computed Tomography (CBCT) and Computed Micro-Tomography (Micro-CT) from a Present and Future Perspective-A Systematic Review.

Authors:  Mirona Paula Palczewska-Komsa; Bartosz Gapiński; Alicja Nowicka
Journal:  J Clin Med       Date:  2022-05-30       Impact factor: 4.964

3.  The effect of a manual instrumentation technique on five types of premolar root canal geometry assessed by microcomputed tomography and three-dimensional reconstruction.

Authors:  Ke-Zeng Li; Yuan Gao; Ru Zhang; Tao Hu; Bin Guo
Journal:  BMC Med Imaging       Date:  2011-06-15       Impact factor: 1.930

Review 4.  C-shaped root canal configuration: A review of literature.

Authors:  Marina Fernandes; Ida de Ataide; Rahul Wagle
Journal:  J Conserv Dent       Date:  2014-07

Review 5.  Aetiology, incidence and morphology of the C-shaped root canal system and its impact on clinical endodontics.

Authors:  A Kato; A Ziegler; N Higuchi; K Nakata; H Nakamura; N Ohno
Journal:  Int Endod J       Date:  2014-03-31       Impact factor: 5.264

6.  Healing outcomes of root canal treatment for C-shaped mandibular second molars: a retrospective analysis.

Authors:  Hye-Ra Ahn; Young-Mi Moon; Sung-Ok Hong; Min-Seock Seo
Journal:  Restor Dent Endod       Date:  2016-08-29

7.  Cleaning Efficiency of Root Canal after Irrigation with New Irrigation Technique: A Scanning Electron Microscopic Study.

Authors:  Linz A Shalan; Hussain F Al-Huwaizi
Journal:  Iran Endod J       Date:  2018

8.  High-resolution micro-CT scanning as an innovative tool for evaluating dental hard tissue development.

Authors:  Guangyan Dong; Qianqian Dong; Yi Liu; Beiyan Lou; Jin Feng; Kejing Wang; Xuedong Zhou; Hongkun Wu
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

9.  Comparison of continuous wave and cold lateral condensation filling techniques in 3D printed simulated C-shape canals instrumented with Reciproc Blue or Hyflex EDM.

Authors:  Anıl Özgün Karatekin; Ali Keleş; Nimet Gençoğlu
Journal:  PLoS One       Date:  2019-11-21       Impact factor: 3.240