Literature DB >> 18792422

Layer-specific anatomical, physiological and functional MRI of the retina.

Timothy Q Duong1, Machelle T Pardue, Peter M Thulé, Darin E Olson, Haiying Cheng, Govind Nair, Yingxia Li, Moon Kim, Xiaodong Zhang, Qiang Shen.   

Abstract

Most retinal imaging has been performed using optical techniques. This paper reviews alternative retinal imaging methods based on MRI performed with spatial resolution sufficient to resolve multiple well-defined retinal layers. The development of these MRI technologies to study retinal anatomy, physiology (blood flow, blood volume, and oxygenation) and function, and their applications to the study of normal retinas, retinal degeneration and diabetic retinopathy in animal models are discussed. Although the spatiotemporal resolution of MRI is poorer than that of optical imaging techniques, it is unhampered by media opacity and can thus image all retinal and pararetinal structures, and has the potential to provide multiple unique clinically relevant data in a single setting and could thus complement existing retinal imaging techniques. In turn, the highly structured retina with well-defined layers is an excellent model for advancing emerging high-resolution anatomical, physiological and functional MRI technologies.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18792422      PMCID: PMC2752861          DOI: 10.1002/nbm.1311

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  117 in total

1.  Simplified laser-speckle-imaging analysis method and its application to retinal blood flow imaging.

Authors:  Haiying Cheng; Timothy Q Duong
Journal:  Opt Lett       Date:  2007-08-01       Impact factor: 3.776

2.  A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging.

Authors:  E C Wong; R B Buxton; L R Frank
Journal:  Magn Reson Med       Date:  1998-09       Impact factor: 4.668

3.  Microspheres method for ocular blood flow measurement in rats: size and dose optimization.

Authors:  Lin Wang; Brad Fortune; Grant Cull; Kyle M McElwain; George A Cioffi
Journal:  Exp Eye Res       Date:  2006-10-25       Impact factor: 3.467

4.  The clearance of manganese chloride in the primate.

Authors:  M C Newland; C Cox; R Hamada; G Oberdörster; B Weiss
Journal:  Fundam Appl Toxicol       Date:  1987-08

Review 5.  Tissue specific perfusion imaging using arterial spin labeling.

Authors:  J A Detre; W Zhang; D A Roberts; A C Silva; D S Williams; D J Grandis; A P Koretsky; J S Leigh
Journal:  NMR Biomed       Date:  1994-03       Impact factor: 4.044

6.  Intraretinal oxygen levels before and after photoreceptor loss in the RCS rat.

Authors:  D Y Yu; S J Cringle; E N Su; P K Yu
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-11       Impact factor: 4.799

7.  Manganese ion enhances T1-weighted MRI during brain activation: an approach to direct imaging of brain function.

Authors:  Y J Lin; A P Koretsky
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

8.  Influence of flickering light on the retinal vessels in diabetic patients.

Authors:  Aleksandra Mandecka; Jens Dawczynski; Marcus Blum; Nicolle Müller; Christoph Kloos; Gunter Wolf; Walthard Vilser; Heike Hoyer; Ulrich Alfons Müller
Journal:  Diabetes Care       Date:  2007-08-29       Impact factor: 19.112

9.  Oxygen distribution and consumption in the cat retina during normoxia and hypoxemia.

Authors:  R A Linsenmeier; R D Braun
Journal:  J Gen Physiol       Date:  1992-02       Impact factor: 4.086

10.  Effects of light and darkness on oxygen distribution and consumption in the cat retina.

Authors:  R A Linsenmeier
Journal:  J Gen Physiol       Date:  1986-10       Impact factor: 4.086

View more
  26 in total

1.  Blood flow MRI of the human retina/choroid during rest and isometric exercise.

Authors:  Yi Zhang; Oscar San Emeterio Nateras; Qi Peng; Carlos A Rosende; Timothy Q Duong
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-06-28       Impact factor: 4.799

2.  Choroidal blood flow decreases with age: an MRI study.

Authors:  Oscar San Emeterio Nateras; Joseph M Harrison; Eric R Muir; Yi Zhang; Qi Peng; Steven Chalfin; Juan E Gutierrez; Daniel A Johnson; Jeffrey W Kiel; Timothy Q Duong
Journal:  Curr Eye Res       Date:  2014-03-21       Impact factor: 2.424

3.  Lamina-specific anatomic magnetic resonance imaging of the human retina.

Authors:  Yi Zhang; Oscar San Emeterio Nateras; Qi Peng; Roman V Kuranov; Joseph M Harrison; Thomas E Milner; Timothy Q Duong
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-09-14       Impact factor: 4.799

Review 4.  MR imaging of papilledema and visual pathways: effects of increased intracranial pressure and pathophysiologic mechanisms.

Authors:  N Passi; A J Degnan; L M Levy
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

5.  Dual-wavelength photothermal optical coherence tomography for imaging microvasculature blood oxygen saturation.

Authors:  Biwei Yin; Roman V Kuranov; Austin B McElroy; Shams Kazmi; Andrew K Dunn; Timothy Q Duong; Thomas E Milner
Journal:  J Biomed Opt       Date:  2013-05       Impact factor: 3.170

6.  Magic angle-enhanced MRI of fibrous microstructures in sclera and cornea with and without intraocular pressure loading.

Authors:  Leon C Ho; Ian A Sigal; Ning-Jiun Jan; Alexander Squires; Zion Tse; Ed X Wu; Seong-Gi Kim; Joel S Schuman; Kevin C Chan
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-08-07       Impact factor: 4.799

7.  Magnetic resonance imaging indicates decreased choroidal and retinal blood flow in the DBA/2J mouse model of glaucoma.

Authors:  William J Lavery; Eric R Muir; Jeffrey W Kiel; Timothy Q Duong
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-02-01       Impact factor: 4.799

8.  Manganese-enhanced MRI (MEMRI) via topical loading of Mn(2+) significantly impairs mouse visual acuity: a comparison with intravitreal injection.

Authors:  Tsen-Hsuan Lin; Chia-Wen Chiang; Kathryn Trinkaus; William M Spees; Peng Sun; Sheng-Kwei Song
Journal:  NMR Biomed       Date:  2014-01-16       Impact factor: 4.044

9.  Long-term effects of neonatal hypoxia-ischemia on structural and physiological integrity of the eye and visual pathway by multimodal MRI.

Authors:  Kevin C Chan; Swarupa Kancherla; Shu-Juan Fan; Ed X Wu
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-12-09       Impact factor: 4.799

Review 10.  Magnetic resonance imaging of the retina.

Authors:  Timothy Q Duong; Eric R Muir
Journal:  Jpn J Ophthalmol       Date:  2009-09-08       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.