Embolic protection devices in patients with renal artery stenosis with chronic renal insufficiency: a clinical study.

Sanjay Misra1, Manuel T Gomes, Verghese Mathew, Gregory W Barsness, Stephen C Textor, Haraldur Bjarnason, Michael A McKusick.   

Abstract

PURPOSE: To present clinical outcomes with the use of embolic protection devices (EPDs) and renal artery stents in patients with chronic renal insufficiency (CRI) and renal artery stenosis (RAS).
MATERIALS AND METHODS: A retrospective study was conducted in 23 patients with RAS and CRI who were treated with renal artery stent placement with an EPD. Follow-up data were obtained through medical records.
RESULTS: In 23 patients (18 men; 78%) with an average age of 69.4 years +/- 11 (range, 46-86 y), 32 renal arteries were treated for worsening renal function (n = 17; 74%) or uncontrolled hypertension and worsening renal function (n = 6; 26%). Nine FilterWire EZ devices were used in eight patients (35%) and 17 SpideRX devices were used in 15 patients (65%). The average follow-up was 8 months +/- 5. After the stent procedure, the mean systolic blood pressure decreased significantly (P < .05) whereas the diastolic pressure remained unchanged. There was a significant increase in the mean estimated glomerular filtration rate from 32.9 mL/min +/- 12.9 at baseline to 41.3 mL/min +/- 13.7 at last follow-up (P < .05). In 96% of patients, there was improvement or stabilization of kidney function. In six of the 17 SpideRX devices (35%), macroscopically evident embolic material was observed in the device after stent placement. There were two minor and two major complications.
CONCLUSIONS: Renal artery stent placement combined with the use of a SpideRX or FilterWire EZ device is associated with an good clinical outcome with a reasonable safety profile.

Entities:  

Mesh:

Year:  2008        PMID: 18789723     DOI: 10.1016/j.jvir.2008.08.002

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  2 in total

1.  Clinical outcomes in patients with renal artery stenosis treated with stent placement with embolic protection compared with those treated with stent alone.

Authors:  Ankaj Khosla; Sanjay Misra; Eddie L Greene; Axel Pflueger; Steve C Textor; Haraldur Bjarnason; Michael A McKusick
Journal:  Vasc Endovascular Surg       Date:  2012-06-11       Impact factor: 1.089

Review 2.  Percutaneous revascularization for ischemic nephropathy: the past, present, and future.

Authors:  Stephen C Textor; Sanjay Misra; Gustavo S Oderich
Journal:  Kidney Int       Date:  2012-11-14       Impact factor: 10.612