Literature DB >> 18787515

A noncontact approach for the evaluation of large artery stiffness: a preliminary study.

Mirko De Melis1, Umberto Morbiducci, Lorenzo Scalise, Enrico P Tomasini, Danae Delbeke, Roel Baets, Luc M Van Bortel, Patrick Segers.   

Abstract

BACKGROUND: The time from carotid to femoral pulse wave propagation (pulse transit time (PTT)) is required to estimate the carotid-femoral pulse wave velocity (PWV), a reliable index for evaluating large artery stiffness.
METHODS: In this work, we propose a novel, noncontact laser-based technique, named optical vibrocardiography (VCG), for evaluating PTT from synchronous recordings of the motion of the skin on the neck and the groin. These measurements, which have been demonstrated to be related to the radial displacement of the underlying blood vessels, were performed on 14 healthy subjects. As validation, applanation tonometry was performed to determine PTT between the carotid and the femoral artery.
RESULTS: PTT evaluated by VCG was not different from applanation tonometry (74.86 +/- 8.63 ms vs. 75.85 +/- 8.61 ms, P = 0.377).
CONCLUSIONS: Our preliminary results demonstrate that laser-based noncontact measurement in young healthy volunteers is feasible, and yields PTTs that are equivalent to those measured using arterial applanation tonometry. Its clinical application can overcome limitations inherent to a contact method like arterial tonometry.

Entities:  

Mesh:

Year:  2008        PMID: 18787515     DOI: 10.1038/ajh.2008.280

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  7 in total

1.  Laser doppler myography (LDMi): A novel non-contact measurement method for the muscle activity.

Authors:  L Scalise; S Casaccia; P Marchionni; I Ercoli; Ep Tomasini
Journal:  Laser Ther       Date:  2013-12-30

2.  Novel Applications of Laser Doppler Vibration Measurements to Medical Imaging.

Authors:  Habib Tabatabai; David E Oliver; John W Rohrbaugh; Christopher Papadopoulos
Journal:  Sens Imaging       Date:  2013-08-13

3.  Detecting carotid stenosis from skin vibrations using Laser Doppler Vibrometry - An in vitro proof-of-concept.

Authors:  Viviana Mancini; Daniela Tommasin; Yanlu Li; Jonathan Reeves; Roel Baets; Steve Greenwald; Patrick Segers
Journal:  PLoS One       Date:  2019-06-20       Impact factor: 3.240

4.  High-Frequency Fluctuations in Post-stenotic Patient Specific Carotid Stenosis Fluid Dynamics: A Computational Fluid Dynamics Strategy Study.

Authors:  Viviana Mancini; Aslak W Bergersen; Jan Vierendeels; Patrick Segers; Kristian Valen-Sendstad
Journal:  Cardiovasc Eng Technol       Date:  2019-04-01       Impact factor: 2.495

5.  Using smart speakers to contactlessly monitor heart rhythms.

Authors:  Anran Wang; Dan Nguyen; Arun R Sridhar; Shyamnath Gollakota
Journal:  Commun Biol       Date:  2021-03-09

6.  Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals.

Authors:  Silvia Seoni; Simeon Beeckman; Yanlu Li; Soren Aasmul; Umberto Morbiducci; Roel Baets; Pierre Boutouyrie; Filippo Molinari; Nilesh Madhu; Patrick Segers
Journal:  Front Physiol       Date:  2022-01-11       Impact factor: 4.566

Review 7.  Novel Methods for Pulse Wave Velocity Measurement.

Authors:  Tânia Pereira; Carlos Correia; João Cardoso
Journal:  J Med Biol Eng       Date:  2015-10-14       Impact factor: 1.553

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.