Effect of delay in sampling on haemoglobin determined by faecal immunochemical tests.

Louise F Brown1, Callum G Fraser.   

Abstract

BACKGROUND: Faeces must be sampled directly onto guaiac-based faecal occult blood test (FOBT) cards since analysis of specimens collected in traditional faeces containers is inappropriate because degradation of haemoglobin continues after faeces have been passed. Newer faecal immunochemical tests (FIT) are replacing FOBT, but it is likely that the practice of obtaining specimens in traditional faeces collection containers for later analysis will continue. The aim of this study was to assess the effect of delay in stool sampling on FIT.
METHODS: Five specimens of faeces from healthy volunteers, all qualitatively FIT negative, were supplemented with whole blood haemolysate to three different FIT positive concentrations. Each sample was analysed daily after 1-14 days delay using a quantitative latex immunoturbidimetric-based FIT and also after five and ten days delay using a qualitative FIT.
RESULTS: Haemoglobin concentrations fell each day, the rate being generally proportional to the original haemoglobin concentration. After eight days delay, no sample had a haemoglobin concentration >100 ng/mL and, after nine days, no sample had a haemoglobin concentration >50 ng/mL. After five days delay, five of the 15 supplemented faeces with initially positive qualitative FIT had negative FIT; after 10 days, none had positive FIT.
CONCLUSION: False-negative results will occur if sampling of fresh faeces into or onto FIT collection devices is delayed. Laboratories that undertake FIT analyses on faeces collected into traditional containers are likely to miss significant neoplasia. FIT collection devices must be used for sampling fresh faeces.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18782817     DOI: 10.1258/acb.2008.008024

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  7 in total

1.  Perspectives of colorectal cancer screening in Germany 2009.

Authors:  Andreas Sieg; Kilian Friedrich
Journal:  World J Gastrointest Endosc       Date:  2009-10-15

2.  Comparison of One versus Two Fecal Immunochemical Tests in the Detection of Colorectal Neoplasia in a Population-Based Colorectal Cancer Screening Program.

Authors:  Sarvenaz Moosavi; Robert Enns; Laura Gentile; Lovedeep Gondara; Colleen McGahan; Jennifer Telford
Journal:  Can J Gastroenterol Hepatol       Date:  2016-12-01

3.  Evaluation of the analytical performance of the novel NS-Prime system and examination of temperature stability of fecal transferrin compared with fecal hemoglobin as biomarkers in a colon cancer screening program.

Authors:  Wael L L Demian; Stacy Collins; Candace Fowler; Jerry McGrath; Scott Antle; Zoë Moores; Deborah Hollohan; Suzanne Lacey; Joseph Banoub; Edward Randell
Journal:  Pract Lab Med       Date:  2015-07-22

4.  Accuracy of a fecal immunochemical test according to outside temperature and travel time.

Authors:  Tobias Niedermaier; Korbinian Weigl; Anton Gies; Michael Hoffmeister; Hermann Brenner
Journal:  Clin Epidemiol       Date:  2018-09-17       Impact factor: 4.790

5.  Experience of adopting faecal immunochemical testing to meet the NICE colorectal cancer referral criteria for low-risk symptomatic primary care patients in Oxfordshire, UK.

Authors:  Brian D Nicholson; Tim James; James E East; David Grimshaw; Maria Paddon; Steve Justice; Jason L Oke; Brian Shine
Journal:  Frontline Gastroenterol       Date:  2018-10-09

Review 6.  Advances in Fecal Occult Blood Tests: the FIT revolution.

Authors:  Graeme P Young; Erin L Symonds; James E Allison; Stephen R Cole; Callum G Fraser; Stephen P Halloran; Ernst J Kuipers; Helen E Seaman
Journal:  Dig Dis Sci       Date:  2014-12-10       Impact factor: 3.199

7.  Faecal immunochemical testing and blood tests for prioritization of urgent colorectal cancer referrals in symptomatic patients: a 2-year evaluation.

Authors:  J A Bailey; J Weller; C J Chapman; A Ford; K Hardy; S Oliver; J R Morling; J A Simpson; D J Humes; A Banerjea
Journal:  BJS Open       Date:  2021-03-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.