Literature DB >> 18781582

Accurate pre-operative localization of pathological parathyroid glands using 11C-methionine PET/CT.

Bich-Ngoc-Thanh Tang1, Rodrigo Moreno-Reyes, Didier Blocklet, Bernard Corvilain, Matteo Cappello, Isabelle Delpierre, France Devuyst, Gaetan Van Simaeys, Serge Goldman.   

Abstract

OBJECTIVE: The pre-operative technique most routinely used to localize pathological parathyroid glands (PPG), prior to minimal access surgery (MAS), relies on 99mTc-sestamibi (MIBI) scintigraphy. Positron emission tomography (PET) using the radiolabelled amino acid 11C-methionine as the tracer agent offers a technological alternative to localize PPG. In this study we evaluated the sensitivity of 11C-methionine PET/CT (MET-PET/CT) for PPG detection and the extent to which MET-PET/CT images may contribute to the planning of surgical procedures.
DESIGN: Thirty patients were included, 22 with primary hyperparathyroidism and eight with secondary hyperparathyroidism. Patients suspected of suffering from parathyroid hyperplasia underwent a complete surgical exploration of the neck region. In those suspected of parathyroid adenoma, surgery was limited to the presumed localization described by MET-PET/CT. To specifically address the additional benefit of the MET-PET/CT in terms of surgical planning and procedure, the surgeon classified the patients into two categories depending on the type of benefit, or the reason for the absence of benefit, occurring in each case. We also compared the sensitivity of MET-PET/CT and MIBI scintigraphy.
RESULTS: The total number of lesions removed was 46 (24 adenomatous and 22 hyperplastic). Globally, MET-PET/CT provided additional benefit to surgery in 15 out of 30 cases (50%). The sensitivity of 11C-methionine PET/CT and MIBI scintigraphy was respectively 92% and 95% for adenoma, and 68% and 59% for hyperplasia, on the basis of available resected lesions.
CONCLUSION: MET-PET/CT appears a reliable technique to guide MAS of parathyroid glands. Copyright (c) 2008 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18781582     DOI: 10.1002/cmmi.243

Source DB:  PubMed          Journal:  Contrast Media Mol Imaging        ISSN: 1555-4309            Impact factor:   3.161


  10 in total

1.  Preoperative ¹¹C-methionine PET/CT enables focused parathyroidectomy in MIBI-SPECT negative parathyroid adenoma.

Authors:  Christina Lenschow; Peter Gassmann; Christian Wenning; Norbert Senninger; Mario Colombo-Benkmann
Journal:  World J Surg       Date:  2015-07       Impact factor: 3.352

2.  ¹⁸F-Fluorocholine PET/CT for localization of hyperfunctioning parathyroid tissue in primary hyperparathyroidism: a pilot study.

Authors:  Luka Lezaic; Sebastijan Rep; Mojca Jensterle Sever; Tomaz Kocjan; Marko Hocevar; Jure Fettich
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-07-26       Impact factor: 9.236

Review 3.  Imaging for primary hyperparathyroidism--an evidence-based analysis.

Authors:  Radu Mihai; Dietmar Simon; Per Hellman
Journal:  Langenbecks Arch Surg       Date:  2009-07-10       Impact factor: 3.445

4.  Diagnostic performance of positron emission tomography using ¹¹C-methionine in patients with suspected parathyroid adenoma: a meta-analysis.

Authors:  Carmelo Caldarella; Giorgio Treglia; Maria Antonietta Isgrò; Alessandro Giordano
Journal:  Endocrine       Date:  2012-07-18       Impact factor: 3.633

Review 5.  [Localization of parathyroid adenomas with C11-methionine PET-CT].

Authors:  T Weber; M Luster
Journal:  Chirurg       Date:  2014-07       Impact factor: 0.955

6.  Detection and Characterization of Parathyroid Adenoma/Hyperplasia for Preoperative Localization: Comparison Between (11)C-Methionine PET/CT and (99m)Tc-Sestamibi Scintigraphy.

Authors:  In Kook Chun; Gi Jeong Cheon; Jin Chul Paeng; Keon Wook Kang; June-Key Chung; Dong Soo Lee
Journal:  Nucl Med Mol Imaging       Date:  2013-07-06

7.  Is C-11 Methionine PET/CT Able to Localise Sestamibi-Negative Parathyroid Adenomas?

Authors:  Theresia Weber; Martin Gottstein; Sabrina Schwenzer; Ambros Beer; Markus Luster
Journal:  World J Surg       Date:  2017-04       Impact factor: 3.352

Review 8.  Use of PET tracers for parathyroid localization: a systematic review and meta-analysis.

Authors:  Wouter P Kluijfhout; Jesse D Pasternak; Frederick Thurston Drake; Toni Beninato; Jessica E Gosnell; Wen T Shen; Quan-Yang Duh; Isabel E Allen; Menno R Vriens; Bart de Keizer; Miguel H Pampaloni; Insoo Suh
Journal:  Langenbecks Arch Surg       Date:  2016-04-16       Impact factor: 3.445

Review 9.  Primary hyperparathyroidism: review and recommendations on evaluation, diagnosis, and management. A Canadian and international consensus.

Authors:  A A Khan; D A Hanley; R Rizzoli; J Bollerslev; J E M Young; L Rejnmark; R Thakker; P D'Amour; T Paul; S Van Uum; M Zakaria Shrayyef; D Goltzman; S Kaiser; N E Cusano; R Bouillon; L Mosekilde; A W Kung; S D Rao; S K Bhadada; B L Clarke; J Liu; Q Duh; E Michael Lewiecki; F Bandeira; R Eastell; C Marcocci; S J Silverberg; R Udelsman; K Shawn Davison; J T Potts; M L Brandi; J P Bilezikian
Journal:  Osteoporos Int       Date:  2016-09-09       Impact factor: 4.507

10.  Evaluation of diagnostic efficacy for localization of parathyroid adenoma in patients with primary hyperparathyroidism undergoing repeat surgery.

Authors:  Anne Hendricks; Christina Lenschow; Matthias Kroiss; Andreas Buck; Ralph Kickuth; Christoph-Thomas Germer; Nicolas Schlegel
Journal:  Langenbecks Arch Surg       Date:  2021-05-16       Impact factor: 3.445

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.