Literature DB >> 18781133

Preoperative 18F-FDG-PET/CT imaging and sentinel node biopsy in the detection of regional lymph node metastases in malignant melanoma.

Baljinder Singh1, Samer Ezziddin, Holger Palmedo, Michael Reinhardt, Holger Strunk, Thomas Tüting, Hans-Jürgen Biersack, Hojjat Ahmadzadehfar.   

Abstract

The objective of this study was to evaluate the role of preoperative 18F-fluorodeoxyglucose-positron emission tomography/computed tomography scanning, preoperative lymphoscintigraphy (LS), and sentinel lymph node biopsy in patients with malignant melanoma. Fifty-two patients (36 men: 16 women; mean age 55.0+/-13.0 years; median age 61 years; range 17-76 years) with malignant melanoma were selected. According to the latest version of the American Joint Committee on Cancer staging system, the disease in the study patients was initially classified as either stage I or II. The other primary tumor characteristics were mean Breslow depth=2.87 mm and median=2 mm; range 1-12.0 mm and Clarks levels III-V. None of the study patients had clinical or radiological evidence of regional lymph node metastatic disease. At least one sentinel node was identified in all patients. Preoperative LS detected a total of 111 sentinel lymph nodes (average 2.13 sentinel lymph node per patient) and demonstrated a single nodal draining basin in 38 (73%) patients and multiple (2-3 draining basins) in the remaining 14 (27%) patients. Fourteen out of the 52 patients (27%) had at least one involved sentinel node. Positron emission tomography was true positive in two patients with a sentinel node greater than 1 cm and false positive in two other patients. In this study, the detection of sentinel lymph node by LS and gamma probe had a sensitivity of 100%. In contrast, 18F-FDG-PET imaging demonstrated very low sensitivity (14.3%; 95% CI, 2.5 to 44%) and positive predictive value (50%; 95% CI, 9 to 90%) for localizing the subclinical nodal metastases. The specificity, net present value, and diagnostic accuracy were 94.7, 75, and 73%, respectively. Preoperative fluorodeoxyglucose-positron emission tomography/computed tomography imaging is not able to substitute LS/sentinel lymph node biopsy in patients at stage I or II.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18781133     DOI: 10.1097/CMR.0b013e32830b363b

Source DB:  PubMed          Journal:  Melanoma Res        ISSN: 0960-8931            Impact factor:   3.599


  11 in total

1.  Positron Lymphography via Intracervical 18F-FDG Injection for Presurgical Lymphatic Mapping in Cervical and Endometrial Malignancies.

Authors:  Jennifer J Mueller; Lawrence T Dauer; Rajmohan Murali; Alexia Iasonos; Neeta Pandit-Taskar; Nadeem R Abu-Rustum; Jan Grimm
Journal:  J Nucl Med       Date:  2020-01-10       Impact factor: 10.057

2.  Impact of Completion Lymph Node Dissection on Patients with Positive Sentinel Lymph Node Biopsy in Melanoma.

Authors:  David Y Lee; Briana J Lau; Kelly T Huynh; Devin C Flaherty; Ji-Hey Lee; Stacey L Stern; Steve J O'Day; Leland J Foshag; Mark B Faries
Journal:  J Am Coll Surg       Date:  2016-01-29       Impact factor: 6.113

3.  Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?

Authors:  Benedikt Michael Schaarschmidt; Johannes Grueneisen; Vanessa Stebner; Joachim Klode; Ingo Stoffels; Lale Umutlu; Dirk Schadendorf; Philipp Heusch; Gerald Antoch; Thorsten Dirk Pöppel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-06-06       Impact factor: 9.236

4.  Contemporary diagnostic imaging modalities for the staging and surveillance of melanoma patients: a meta-analysis.

Authors:  Yan Xing; Yulia Bronstein; Merrick I Ross; Robert L Askew; Jeffrey E Lee; Jeffrey E Gershenwald; Richard Royal; Janice N Cormier
Journal:  J Natl Cancer Inst       Date:  2010-11-16       Impact factor: 13.506

5.  Contrast-enhanced ultrasound imaging in vivo with laser-activated nanodroplets.

Authors:  Heechul Yoon; Steven K Yarmoska; Alexander S Hannah; Changhan Yoon; Kristina A Hallam; Stanislav Y Emelianov
Journal:  Med Phys       Date:  2017-05-16       Impact factor: 4.071

Review 6.  Blind spots at oncological CT: lessons learned from PET/CT.

Authors:  Jacob Sosna; Steven J Esses; Nikolay Yeframov; Hanna Bernstine; Tamar Sella; Shifra Fraifeld; Jonathan B Kruskal; David Groshar
Journal:  Cancer Imaging       Date:  2012-08-10       Impact factor: 3.909

Review 7.  F-18-fluoro-2-deoxyglucose positron emission tomography (PET) and PET/computed tomography imaging in primary staging of patients with malignant melanoma: a systematic review.

Authors:  Milly A Schröer-Günther; Robert F Wolff; Marie E Westwood; Fülöp J Scheibler; Christoph Schürmann; Brigitta G Baumert; Stefan Sauerland; Jos Kleijnen
Journal:  Syst Rev       Date:  2012-12-13

8.  Comparison between F-Fluorodeoxyglucose Positron Emission Tomography and Sentinel Lymph Node Biopsy for Regional Lymph Nodal Staging in Patients with Melanoma: A Review of the Literature.

Authors:  Paoletta Mirk; Giorgio Treglia; Marco Salsano; Pietro Basile; Alessandro Giordano; Lorenzo Bonomo
Journal:  Radiol Res Pract       Date:  2011-12-22

9.  Ultrasound, CT, MRI, or PET-CT for staging and re-staging of adults with cutaneous melanoma.

Authors:  Jacqueline Dinnes; Lavinia Ferrante di Ruffano; Yemisi Takwoingi; Seau Tak Cheung; Paul Nathan; Rubeta N Matin; Naomi Chuchu; Sue Ann Chan; Alana Durack; Susan E Bayliss; Abha Gulati; Lopa Patel; Clare Davenport; Kathie Godfrey; Manil Subesinghe; Zoe Traill; Jonathan J Deeks; Hywel C Williams
Journal:  Cochrane Database Syst Rev       Date:  2019-07-01

10.  Evaluation of 18F-FDG PET/CT Parameters for Detection of Lymph Node Metastasis in Cutaneous Melanoma.

Authors:  Jongtae Cha; Soyoung Kim; Jiyoung Wang; Mijin Yun; Arthur Cho
Journal:  Nucl Med Mol Imaging       Date:  2017-09-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.