Literature DB >> 18780822

Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT.

Paul Stolzmann1, Thomas Frauenfelder, Thomas Pfammatter, Nicole Peter, Hans Scheffel, Mario Lachat, Bernhard Schmidt, Borut Marincek, Hatem Alkadhi, Thomas Schertler.   

Abstract

PURPOSE: To assess the diagnostic performance of dual-energy dual-source computed tomography (CT) in the detection of endoleaks after endovascular abdominal aortic aneurysm (AAA) repair.
MATERIALS AND METHODS: This study was local ethics board approved, and written informed consent was obtained from all patients. One hundred eighteen patients (21 women, 97 men; mean age, 74 years +/- 8 [standard deviation]) underwent follow-up dual-energy dual-source CT during the nonenhanced, arterial, and delayed phases after AAA repair. Delayed phase CT images were acquired in the dual-energy mode for reconstruction of virtual nonenhanced images. Two blinded and independent readers evaluated the data for the presence or absence of endoleaks during three reading sessions: Standard nonenhanced, arterial phase, and delayed phase images were read during session A; virtual nonenhanced, arterial phase, and delayed phase images, during session B; and virtual nonenhanced and delayed phase images, during session C. Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) were calculated, with the session A image data set as the reference standard. Radiation dose parameters were estimated.
RESULTS: Reading session A revealed that 52 (44%) of 118 patients had endoleaks. Overall sensitivity, specificity, NPV, and PPV for CT endoleak detection during sessions B and C were identical: 100%, 97%, 100%, and 96%, respectively. The accuracy of the session B and session C readings was not significantly different from that of the session A reading (P = .50). The effective radiation dose in the image acquisition protocol involving one dual-energy scan was significantly (P < .001) lower than the effective doses in the protocols involving standard triple-phase scanning (mean difference, 61%) and standard nonenhanced and delayed phase scanning (mean difference, 41%).
CONCLUSION: Compared with standard protocols, one dual-energy dual-source CT scan performed during the delayed phase with reconstruction of virtual nonenhanced images enables detection of endoleaks after endovascular AAA repair with high accuracy and a considerably lower radiation dose. (c) RSNA, 2008.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18780822     DOI: 10.1148/radiol.2483080193

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  40 in total

1.  Endovascular therapy for thoracic aortic aneurysms: state of the art in 2012.

Authors:  Nicolas A Brozzi; Eric E Roselli
Journal:  Curr Treat Options Cardiovasc Med       Date:  2012-04

Review 2.  [Strategies for reducing the CT radiation dose].

Authors:  S T Schindera; C Nauer; R Treier; P Trueb; G von Allmen; P Vock; Z Szucs-Farkas
Journal:  Radiologe       Date:  2010-12       Impact factor: 0.635

3.  Preliminary experience with abdominal dual-energy CT (DECT): true versus virtual nonenhanced images of the liver.

Authors:  C N De Cecco; V Buffa; S Fedeli; A Vallone; R Ruopoli; M Luzietti; V Miele; M Rengo; M Maurizi Enrici; P Fina; A Laghi; V David
Journal:  Radiol Med       Date:  2010-09-17       Impact factor: 3.469

4.  Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study.

Authors:  Christoph Karlo; Arno Lauber; Robert Paul Götti; Stephan Baumüller; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Bernhard Schmidt; Borut Marincek; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-08-15       Impact factor: 5.315

5.  Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study.

Authors:  Long-Jiang Zhang; Jin Peng; Sheng-Yong Wu; Z Jane Wang; Xin-Sheng Wu; Chang-Sheng Zhou; Xue-Man Ji; Guang-Ming Lu
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

6.  Pilot multi-reader study demonstrating potential for dose reduction in dual energy hepatic CT using non-linear blending of mixed kV image datasets.

Authors:  Anja Apel; Joel G Fletcher; Jeff L Fidler; David M Hough; Lifeng Yu; Luis S Guimaraes; Matthias E Bellemann; Cynthia H McCollough; David R Holmes; Christian D Eusemann
Journal:  Eur Radiol       Date:  2010-09-29       Impact factor: 5.315

7.  Virtual nonenhanced abdominal dual-energy MDCT: Analysis of image characteristics.

Authors:  Jacob Sosna; Shmuel Mahgerefteh; Liran Goshen; Galit Kafri; Galit Aviram; Arye Blachar
Journal:  World J Radiol       Date:  2012-04-28

Review 8.  Complications of endovascular aneurysm repair of the thoracic and abdominal aorta: evaluation and management.

Authors:  Dania Daye; T Gregory Walker
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

Review 9.  Computed tomography--old ideas and new technology.

Authors:  Dominik Fleischmann; F Edward Boas
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

Review 10.  Newer CT applications and their alternatives: what is appropriate in children?

Authors:  R Paul Guillerman
Journal:  Pediatr Radiol       Date:  2011-08-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.