Literature DB >> 18780125

Failure of small joint arthrodesis from resorption around a compression screw in a patient with lupus-associated arthritis mutilans: case report.

Oluseyi Aliu1, David T Netscher, Marcia Peltier.   

Abstract

We report the unusual case of a patient with systemic lupus erythematosus (SLE)-associated arthritis mutilans. Arthritis mutilans is a variant of erosive arthritis that is more commonly reported with psoriatic and rheumatoid arthritis and not with SLE. Joint fusion has been shown to be the most effective measure to preserve bone length and prevent further erosive joint changes in arthritis mutilans. We attempted to enhance success of a thumb interphalangeal joint fusion in our patient by adding compression across the fusion with implant screws, given the difficulty of achieving solid bone fusion ordinarily. Osteolysis around the compression screw resulted in arthrodesis failure. We were finally able to achieve successful fusion with iliac crest corticocancellous bone grafts and Kirschner wire fixation. Implant athroplasty in patients with bone loss is risky as it often furthers joint instability because of bone resorption around the prosthesis. This is a point of caution regarding use of any implant (including large screws) in patients with arthritis mutilans, as osteolysis around the implant may occur.

Entities:  

Year:  2007        PMID: 18780125      PMCID: PMC2528981          DOI: 10.1007/s11552-007-9055-1

Source DB:  PubMed          Journal:  Hand (N Y)        ISSN: 1558-9447


  16 in total

1.  Rheumatism and psoriasis: a re-evaluation.

Authors:  V WRIGHT
Journal:  Am J Med       Date:  1959-09       Impact factor: 4.965

2.  Hand reconstruction in arthritis mutilans. A case report.

Authors:  A I Froimson
Journal:  J Bone Joint Surg Am       Date:  1971-10       Impact factor: 5.284

3.  Arthritis mutilans.

Authors:  D N Golding
Journal:  Rheumatism       Date:  1965-10

4.  Hand involvement in psoriatic arthritis.

Authors:  M R Belsky; P Feldon; L H Millender; E A Nalebuff; C Phillips
Journal:  J Hand Surg Am       Date:  1982-03       Impact factor: 2.230

5.  The psoriatic hand.

Authors:  O A Kapasi; L K Ruby; K Calney
Journal:  J Hand Surg Am       Date:  1982-09       Impact factor: 2.230

6.  Opera-glass hand in rheumatoid arthritis.

Authors:  E A Nalebuff; J Garrett
Journal:  J Hand Surg Am       Date:  1976-11       Impact factor: 2.230

7.  The surgical treatment of hand deformities in systemic lupus erythematosis.

Authors:  G J Dray; L H Millender; E A Nalebuff; C Philips
Journal:  J Hand Surg Am       Date:  1981-07       Impact factor: 2.230

Review 8.  Surgery of systemic lupus erythematosus arthritis of the hand.

Authors:  E A Nalebuff
Journal:  Hand Clin       Date:  1996-08       Impact factor: 1.907

9.  Psoriatic arthritis. Follow-up study.

Authors:  M E Roberts; V Wright; A G Hill; A C Mehra
Journal:  Ann Rheum Dis       Date:  1976-06       Impact factor: 19.103

10.  Psoriatic arthritis mutilans: digital distraction lengthening: pathophysiologic and current therapeutic review.

Authors:  R L Walton; R E Brown; D F Giansiracusa
Journal:  J Hand Surg Am       Date:  1988-07       Impact factor: 2.230

View more
  2 in total

Review 1.  Arthritis mutilans.

Authors:  Amir Haddad; Vinod Chandran
Journal:  Curr Rheumatol Rep       Date:  2013-04       Impact factor: 4.592

Review 2.  Silicone and Pyrocarbon Artificial Finger Joints.

Authors:  F A Alnaimat; H A Owida; A Al Sharah; M Alhaj; Mohammad Hassan
Journal:  Appl Bionics Biomech       Date:  2021-06-03       Impact factor: 1.781

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.