Literature DB >> 18779664

Menicon Z rigid gas permeable lenses for keratoconus and irregular corneas: a retrospective case series.

Loretta B Szczotka-Flynn1, Shamil Patel.   

Abstract

PURPOSE: The tisilfocon A (Menicon Z) rigid gas permeable (RGP) contact lens polymer has the highest oxygen permeability (Dk) value of any RGP lens material. To our knowledge there is no published literature documenting the success of this material in fitting contact lenses to highly irregular and diseased corneas.
METHODS: A retrospective medical record review of 40 consecutive patients (64 eyes) who had worn lenses made in the Menicon Z RGP material was performed. All patients had some form of corneal pathology and were fitted in a single tertiary care hospital-based contact lens service.
RESULTS: Menicon Z contact lenses were fit to 33 eyes of 20 patients with keratoconus (KC) and 31 eyes of 23 patients with irregular corneas. The irregular cornea group comprised 28 eyes of 21 patients after corneal surgery, 1 eye with ocular cicatricial pemphigoid and 2 eyes of 1 patient with chronic staphylococcal blepharo-keratoconjuncitivitis. Treatment goals included acceptable corneal physiology, comfort, and visual acuity. In the KC group, there was an 82% (27/33 eyes) success rate as measured by the treatment goals. Mean duration of wear for successful patients was 2.5 years (0.5-5 years). Only 12% (4/33 eyes) failed directly due to inability of the Menicon Z material to perform adequately while another material was acceptable. In the irregular surface group (surgical and ocular surface disease), there was a 74% (23/31 eyes) success rate. Mean duration of wear for successful patients in this group is 2.79 years (3 months-7 years). Only 3% (1/31 eyes) failed directly due to inability of the Menicon Z material to perform adequately while another material was acceptable.
CONCLUSIONS: The tisilfocon A hyper Dk lens material maintains clinically acceptable corneal health and clinically acceptable visual acuity for patients with KC and irregular corneal surfaces. In this series of patients with complicated corneal disease, the most failures were due to design issues and discomfort not related to the Menicon Z material. The Menicon Z material was inadequate in only 8% of eyes, whereas another RGP material was successful. Most patients with irregular corneas in a tertiary care center can be successfully fit with the tisilfocon A RGP material for visual rehabilitation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18779664     DOI: 10.1097/ICL.0b013e31817f6db0

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  5 in total

1.  Bevel toric multicurve rigid gas-permeable lens for keratoconus.

Authors:  Ryoji Yanai; Kiichi Ueda; Koh-Hei Sonoda
Journal:  Jpn J Ophthalmol       Date:  2012-12-07       Impact factor: 2.447

2.  Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses.

Authors:  Qing Yu; Jiang-Xiu Wu; He-Ning Zhang; Sheng Ye; Shi-Qi Dong; Chen-Hao Zhang
Journal:  Int J Ophthalmol       Date:  2013-04-18       Impact factor: 1.779

Review 3.  Current perspectives in the management of keratoconus with contact lenses.

Authors:  Li Lim; Elizabeth Wen Ling Lim
Journal:  Eye (Lond)       Date:  2020-07-08       Impact factor: 3.775

4.  Clinical evaluation of flat peripheral curve design with aspherical-curve and multi-curve hard contact lenses for keratoconus.

Authors:  Takashi Kumanomido; Kazutaka Kamiya; Masahide Takahashi; Tatsuhiko Tsujisawa; Hideki Hayakawa; Wakako Ando; Yoshikazu Utsumi; Nobuyuki Shoji
Journal:  PLoS One       Date:  2022-02-08       Impact factor: 3.240

5.  Fitting Tips and Visual Rehabilitation of Irregular Cornea with a New Design of Corneoscleral Contact Lens: Objective and Subjective Evaluation.

Authors:  Waleed Ali Abou Samra; Amani E Badawi; Hanem Kishk; Ayman Abd El Ghafar; Mohamed M Elwan; Hossam Youssef Abouelkheir
Journal:  J Ophthalmol       Date:  2018-02-01       Impact factor: 1.909

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.