Literature DB >> 18779617

Sinusoidal obstructive syndrome diagnosed with superparamagnetic iron oxide-enhanced magnetic resonance imaging in patients with chemotherapy-treated colorectal liver metastases.

Janice Ward1, James A Guthrie, Maria B Sheridan, Sheila Boyes, Jonathan T Smith, Daniel Wilson, Judy I Wyatt, Darren Treanor, Philip J Robinson.   

Abstract

PURPOSE: To assess the predictive value of superparamagnetic iron oxide (SPIO) -enhanced T2-weighted gradient echo (GRE) imaging to determine the presence and severity of sinusoidal obstructive syndrome (SOS). PATIENTS AND METHODS: Sixty hepatic resection patients with colorectal metastases treated with chemotherapy underwent unenhanced magnetic resonance imaging (MRI) followed by T2-weighted GRE sequences obtained after SPIO. The images were reviewed in consensus by two experienced observers who determined the presence and severity of linear and reticular hyperintensities, indicating SOS-type liver injury, using a 4-point ordinal scale. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% CIs for the detection of SOS were calculated.
RESULTS: Twenty-four of 60 patients had moderate to severe SOS on MRI. MRI achieved a sensitivity of 87% (95% CI, 66% to 97%), specificity of 89% (95% CI, 75% to 97%), PPV of 83% (95% CI, 63% to 95%), and NPV of 92% (95% CI, 77% to 98%). SOS was never found at surgery or histology in patients whose background liver parenchyma was normal on SPIO-enhanced MRI.
CONCLUSION: SOS is present in a significant proportion of patients with treated colorectal metastases and is effectively detected on SPIO-enhanced T2-weighted GRE images.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18779617     DOI: 10.1200/JCO.2008.16.1893

Source DB:  PubMed          Journal:  J Clin Oncol        ISSN: 0732-183X            Impact factor:   44.544


  30 in total

Review 1.  Hepatic radiation toxicity: avoidance and amelioration.

Authors:  Chandan Guha; Brian D Kavanagh
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

2.  Pre-resectional Radiofrequency Ablation as a Neoadjuvant in situ Tumor Vaccine.

Authors:  Fumito Ito; Sharon S Evans
Journal:  J Vaccines Vaccin       Date:  2016-03-09

Review 3.  Imaging of pathology involving the space around the hepatic veins: "perivenous pattern".

Authors:  Ali Devrim Karaosmanoğlu; Mehmet Ruhi Onur; Mustafa Nasuh Özmen; Deniz Akata; Muşturay Karçaaltıncaba
Journal:  Diagn Interv Radiol       Date:  2018 Mar-Apr       Impact factor: 2.630

4.  Accuracy of gadoxetic acid-enhanced magnetic resonance imaging for the diagnosis of sinusoidal obstruction syndrome in patients with chemotherapy-treated colorectal liver metastases.

Authors:  Na-Young Shin; Myeong-Jin Kim; Joon Seok Lim; Mi-Suk Park; Yong-Eun Chung; Jin-Young Choi; Ki Whang Kim; Young-Nyun Park
Journal:  Eur Radiol       Date:  2011-11-23       Impact factor: 5.315

5.  Genetic predisposition resulting in sinusoidal obstruction syndrome in a patient with resected sigmoid cancer on adjuvant oxaliplatin.

Authors:  Si Xuan Koo; Sock Hoai Chan; Joanne Ngeow
Journal:  BMJ Case Rep       Date:  2016-01-04

Review 6.  [Surgical treatment of liver metastases].

Authors:  M Loss; E M Jung; M N Scherer; S A Farkas; H J Schlitt
Journal:  Chirurg       Date:  2010-06       Impact factor: 0.955

7.  Noninvasive assessment of hepatic sinusoidal obstructive syndrome using acoustic radiation force impulse elastography imaging: A proof-of-concept study in rat models.

Authors:  So Hyun Park; Seung Soo Lee; Ji-Youn Sung; Kiyong Na; Hyoung Jung Kim; So Yeon Kim; Beom Jin Park; Jae Ho Byun
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

Review 8.  The effects of cancer chemotherapy on liver imaging.

Authors:  Philip J A Robinson
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

9.  Magnetic resonance imaging flowmetry demonstrates portal vein dilatation subsequent to oxaliplatin therapy in patients with colorectal liver metastasis.

Authors:  Jozef Urdzik; Tomas Bjerner; Alkwin Wanders; Frans Duraj; Ulf Haglund; Agneta Norén
Journal:  HPB (Oxford)       Date:  2012-08-20       Impact factor: 3.647

Review 10.  [Functional MR imaging of the liver].

Authors:  A Wibmer; R Nolz; M Trauner; A Ba-Ssalamah
Journal:  Radiologe       Date:  2015-12       Impact factor: 0.635

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.