Literature DB >> 18779067

Continuous and discrete data rebinning in time-of-flight PET.

Michel Defrise1, Vladimir Panin, Christian Michel, Michael E Casey.   

Abstract

This paper investigates data compression methods for time-of-flight (TOF) positron emission tomography (PET), which rebin the 3-D TOF measurements into a set of 2-D TOF data for a stack of transaxial slices. The goal of this work is to develop rebinning algorithms that are more accurate than the TOF single-slice-rebinning (TOF-SSRB) method proposed by Mullani in 1982. Two approaches are explored. The first one is based on a partial differential equation, which expresses a consistency condition for TOF-PET data with a Gaussian TOF profile. From this equation we derive an analytical rebinning algorithm, which is unbiased in the limit of continuous sampling. The second approach is discrete: each 2-D rebinned data sample is calculated as a linear combination of the 3-D TOF samples in the same axial plane parallel to the axis of the scanner. The coefficients of the linear combination are precomputed by optimizing a cost function which enforces both accuracy and good variance reduction, models the TOF profile, the axial PSF of the LORs, and the specific sampling scheme of the scanner. Measurements of a thorax phantom on a prototype TOF-PET scanner with a resolution of 550 ps show that the proposed discrete method improves the bias-variance trade-off and is a promising alternative to TOF-SSRB when data compression is required to achieve clinically acceptable reconstruction time.

Entities:  

Mesh:

Year:  2008        PMID: 18779067     DOI: 10.1109/TMI.2008.922688

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  A unified Fourier theory for time-of-flight PET data.

Authors:  Yusheng Li; Samuel Matej; Scott D Metzler
Journal:  Phys Med Biol       Date:  2015-12-22       Impact factor: 3.609

2.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

3.  Exact and approximate Fourier rebinning of PET data from time-of-flight to non time-of-flight.

Authors:  Sanghee Cho; Sangtae Ahn; Quanzheng Li; Richard M Leahy
Journal:  Phys Med Biol       Date:  2009-01-06       Impact factor: 3.609

4.  Joint estimation of activity image and attenuation sinogram using time-of-flight positron emission tomography data consistency condition filtering.

Authors:  Quanzheng Li; Hao Li; Kyungsang Kim; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2017-04-26

5.  Optimal rebinning of time-of-flight PET data.

Authors:  Sangtae Ahn; Sanghee Cho; Quanzheng Li; Yanguang Lin; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2011-05-02       Impact factor: 10.048

6.  Transmission-less attenuation estimation from time-of-flight PET histo-images using consistency equations.

Authors:  Yusheng Li; Michel Defrise; Scott D Metzler; Samuel Matej
Journal:  Phys Med Biol       Date:  2015-08-12       Impact factor: 3.609

7.  Recent developments in time-of-flight PET.

Authors:  S Vandenberghe; E Mikhaylova; E D'Hoe; P Mollet; J S Karp
Journal:  EJNMMI Phys       Date:  2016-02-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.