Literature DB >> 18778930

Fabrication of microband glucose biosensors using a screen-printing water-based carbon ink and their application in serum analysis.

R M Pemberton1, R Pittson, N Biddle, J P Hart.   

Abstract

Microband glucose biosensors were fabricated by screen-printing a water-based carbon ink formulation containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, then insulating and sectioning through the thick (20mum) film to expose a 3mm-long working electrode edge. The performance of these biosensors for glucose analysis was investigated at 25 degrees C. Voltammetry in glucose-containing buffer solutions established that an operating potential of +0.4V vs. Ag/AgCl was suitable for analysis under both stirring and quiescent conditions. The influence of pH on biosensor performance was established and an operational pH of 8.0 was selected. Steady-state responses were obtained under quiescent conditions, suggesting a mixed mechanism predominated by radial diffusion, indicative of microelectrode behaviour. Calibration studies obtained with these biosensors showed steady-state currents that were linearly dependent on glucose concentration from the limit of detection (0.27mM) up to 2.0mM, with a precision for replicate biosensors of 6.2-10.7%. When applied to the determination of glucose in human serum, the concentration compared favourably to that determined by a spectroscopic method. These results have demonstrated a simple means of fabricating biosensors for glucose measurement and determination in situations where low-current real-time monitoring under quiescent conditions would be desirable.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18778930     DOI: 10.1016/j.bios.2008.07.035

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Future opportunities for advancing glucose test device electronics.

Authors:  Brian R Young; Teresa L Young; Margaret K Joyce; Spencer I Kennedy; Massood Z Atashbar
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

2.  Fabrication and evaluation of a micro(bio)sensor array chip for multiple parallel measurements of important cell biomarkers.

Authors:  Roy M Pemberton; Timothy Cox; Rachel Tuffin; Guido A Drago; John Griffiths; Robin Pittson; Graham Johnson; Jinsheng Xu; Ian C Sage; Rhodri Davies; Simon K Jackson; Gerry Kenna; Richard Luxton; John P Hart
Journal:  Sensors (Basel)       Date:  2014-10-30       Impact factor: 3.576

Review 3.  Recent Advances in the Fabrication and Application of Screen-Printed Electrochemical (Bio)Sensors Based on Carbon Materials for Biomedical, Agri-Food and Environmental Analyses.

Authors:  Gareth Hughes; Kelly Westmacott; Kevin C Honeychurch; Adrian Crew; Roy M Pemberton; John P Hart
Journal:  Biosensors (Basel)       Date:  2016-09-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.