Literature DB >> 18778036

Automated liquid injection field desorption/ionization for Fourier transform ion cyclotron resonance mass spectrometry.

Donald F Smith1, Tanner M Schaub, Ryan P Rodgers, Christopher L Hendrickson, Alan G Marshall.   

Abstract

We describe automation of liquid injection field desorption/ionization (LIFDI) for reproducible sample application, improved spectral quality, and high-throughput analyses. A commercial autosampler provides reproducible and unattended sample application. A custom-built field desorption (FD) controller allows data station or front panel control of source parameters including high-voltage limit/ramp rate, emitter heating current limit/ramp rate, and feedback control of emitter heating current based on ion current measurement. Automated LIFDI facilitates ensemble averaging of hundreds of Fourier transform ion cyclotron resonance mass spectra for increased dynamic range, mass accuracy, and S/N ratio relative to single-application FD experiments, as shown here for a South American crude oil. This configuration can be adapted to any mass spectrometer with an LIFDI probe.

Entities:  

Year:  2008        PMID: 18778036     DOI: 10.1021/ac801085r

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  A liquid injection field desorption/ionization-electrospray ionization combination source for a fourier transform ion cyclotron resonance mass spectrometer.

Authors:  H Bernhard Linden; Jürgen H Gross
Journal:  J Am Soc Mass Spectrom       Date:  2011-10-18       Impact factor: 3.109

2.  Self-Supplied Liquid Injection Field Desorption/Ionization Ion Source for an Orthogonal Time-of-Flight Instrument.

Authors:  Mathias H Linden; H Bernhard Linden; Norbert Nieth; Jürgen H Gross
Journal:  J Am Soc Mass Spectrom       Date:  2019-08-02       Impact factor: 3.109

3.  From the discovery of field ionization to field desorption and liquid injection field desorption/ionization-mass spectrometry-A journey from principles and applications to a glimpse into the future.

Authors:  Jürgen H Gross
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2020-06-30       Impact factor: 1.067

4.  Negative-ion field desorption revitalized by using liquid injection field desorption/ionization-mass spectrometry on recent instrumentation.

Authors:  Mathias H Linden; H Bernhard Linden; Jürgen H Gross
Journal:  Anal Bioanal Chem       Date:  2021-09-07       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.